The
N3700
load
board
feature
enables
the
N3700
(A10
and
A20)
to
operate
in
a
SATA-only
storage
environment.
If
the
N3700
load
board
is
ordered,
the
N3700
is
ordered
with
no
Fibre
Channel
hard
drives
and
only
EXN1000s
(SATA
drives)
are
attached
to
the
storage
controller.
Attention:
If
your
N3700
storage
system
shipped
with
load
boards,
exactly
two
load
boards
are
installed
in
the
system.
The
two
load
boards
must
be
installed
in
bays
0
and
1.
Attention:
Depending
on
the
design
of
your
N3700
CPU
module,
direct
connections
to
expansion
units
must
be
made
with
either
Fibre
Channel
copper
cables
or
Fibre
Channel
optical
cables,
as
described
in
the
following
bullets.
Copper
or
optical
cables
are
ordered
with
the
expansion
unit.
v
For
direct
connections
to
N3700
early
CPU
module
designs:
Use
NAS-to-EXP
Fibre
Channel
copper
cables
(FC
#2020
or
2022).
For
attachment
to
an
N3700
Model
A10,
one
NAS-to-EXP
Fibre
Channel
copper
cable
is
required.
For
attachment
to
an
N3700
Model
A20,
two
NAS-to-EXP
Fibre
Channel
copper
cables
are
required.
v
For
direct
connections
to
N3700
current
CPU
module
designs:
Use
an
LC-to-LC
Fibre
Channel
optical
cable
and
two
SFPs
for
attachment
to
an
N3700
Model
A10.
Use
two
LC-to-LC
Fibre
Channel
optical
cables
and
four
SFPs
for
attachment
to
an
N3700
Model
A20.
For
more
information
about
the
differences
between
the
early
and
current
N3700
CPU
module
designs,
see
Connecting
your
N3700
storage
system
to
a
power
source
The
N3700
storage
systems
and
expansion
unit
disk
shelves
are
shipped
with
redundant
power
supplies,
referred
to
as
PSU1
and
PSU2.
Each
power
supply
has
its
own
AC
power
cord.
You
should
have
separate
circuit
breakers
for
each
power
supply
to
ensure
power
redundancy.
For
information
on
connecting
your
N3700
to
a
power
source,
see
the
Installation
and
Setup
Instructions
for
your
storage
system.
Connecting
to
third-party
devices
or
Fibre
Channel
switches
You
can
connect
third-party
devices
to
your
N3700
storage
system
through
an
optical
Fibre
Channel
interface
using
any
Fibre
Channel
port
on
the
back
of
the
chassis.
Refer
to
the
documentation
that
comes
with
the
third-party
device
for
connection
information.
Attention:
On
all
N3700
storage
systems,
Port
C
is
designated
for
use
in
connections
to
third-party
devices.
Rules
for
connecting
the
third-party
devices
Observe
the
following
rules
for
connecting
the
third-party
devices:
v
Port
C
is
designated
for
use
in
connections
to
third-party
devices.
Port
C
is
the
leftmost
port
on
the
bottom
CPU
module.
v
For
N3700
storage
systems
with
the
current
CPU
module
design,
you
must
plug
an
SFP
module
into
port
C
before
cabling
or
terminating
it.
8
IBM
System
Storage
N
series:
N3700
Hardware
and
Service
Guide
Содержание System Storage N3700
Страница 1: ...IBM System Storage N series N3700 Hardware and Service Guide GA32 0515 03...
Страница 2: ......
Страница 3: ...IBM System Storage N series N3700 Hardware and Service Guide GA32 0515 03...
Страница 18: ...xvi IBM System Storage N series N3700 Hardware and Service Guide...
Страница 20: ...xviii IBM System Storage N series N3700 Hardware and Service Guide...
Страница 52: ...26 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 68: ...42 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 80: ...54 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 82: ...56 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 98: ...72 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 102: ...76 IBM System Storage N series N3700 Hardware and Service Guide...
Страница 105: ......
Страница 106: ...NA 210 01254_A0 Printed in USA GA32 0515 03...