System
reference
code
A6005082
Here
are
some
possible
reasons
you
received
system
reference
code
(SRC)
A6005082.
v
If
the
system
displays
this
SRC,
it
typically
means
that
a
console
was
found
but
lost
the
console
connection.
v
If
the
console
is
reassigned
and
the
system
can
locate
a
console,
the
SRC
is
no
longer
shown.
v
The
console
type
does
not
affect
this
SRC.
v
Only
issued
in
attended
mode
IPLs.
Failure
to
display
D1008065
and
D1008066
automatically
after
calling
the
function
When
working
with
models
that
have
a
double
row
for
the
Function/Data
display
portion
of
the
control
panel,
calling
the
function
65
or
66,
the
control
panel
might
not
automatically
display
the
resulting
system
reference
code
(SRC).
In
these
cases,
you
have
to
do
a
function
11
in
order
to
determine
whether
the
function
65
or
66
completed
successfully.
If
the
function
did
not
complete
successfully,
that
is,
if
the
SRC
did
not
display
automatically:
1.
Using
the
control
panel
or
the
remote
control
panel,
press
the
Up
or
Down
buttons
until
11
is
shown.
2.
Press
Enter
.
Related
tasks
Under
certain
circumstances,
a
directly
attached
console
will
fail
to
connect.
IPL
step
C6004031
takes
longer
than
expected
The
i5/OS
operating
system
can
detect
the
hardware
resource
for
a
console.
Depending
on
what
other
console-capable
resources
might
be
found
plus
the
time
it
takes
to
walk
the
bus,
this
activity
has
increased
the
amount
of
time
spent
at
this
IPL
stepin
the
startup
process.
Troubleshooting
remote
control
panel
and
virtual
control
panel
problems
When
setting
up
your
initial
connection,
you
might
encounter
problems
accessing
your
control
panels.
Related
reference
A
virtual
control
panel
(VCP)
connects
to
the
system
through
a
serial
cable.
With
VCP,
you
can
perform
most
of
the
control
panel
functions
from
a
local
location
only.
Remote
control
panel
fails
to
start
If
your
remote
control
panel
fails
to
start,
verify
these
items.
v
Verify
that
the
cables
are
properly
connected.
Note:
Directly
connected
remote
control
panels
are
no
longer
supported.
v
Verify
that
the
resources
of
the
PC
are
free
of
address
or
interrupt
request
(IRQ)
conflicts.
Operations
Console
uses
addresses
in
the
range
of
192.168.0.0
to
192.168.0.255.
If
you
run
any
software
that
makes
your
PC
SOCKS-enabled,
check
your
SOCKS
configuration
and
make
sure
that
the
entry
is:
Direct
192.168.0.0
255.255.255.0
A
SOCKS-enabled
PC
accesses
the
Internet
through
a
firewall,
such
as
Microsoft
Proxy
Client,
Hummingbird
SOCKS
Client,
or
others.
v
If
you
are
connecting
via
a
network,
another
reason
the
remote
control
panel
fails
to
start
may
be
that
either
the
user
ID
or
service
tools
device
ID
being
used
does
not
have
permission
to
use
the
remote
control
panel.
Related
reference
108
System
i:
Connecting
to
System
i
Operations
Console
|
|
|
|
Содержание System i
Страница 1: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Страница 2: ......
Страница 3: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Страница 8: ...vi System i Connecting to System i Operations Console ...
Страница 120: ...112 System i Connecting to System i Operations Console ...
Страница 124: ...116 System i Connecting to System i Operations Console ...
Страница 125: ......
Страница 126: ... Printed in USA ...