![IBM ServeRAID-4 Ultra160 Series Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/ibm/serveraid-4-ultra160-series/serveraid-4-ultra160-series_user-reference_3443970042.webp)
Selecting a RAID level and performance tuning
When selecting a RAID level for your system, consider the following:
RAID level
Data
redundancy
Hard disk drive
capacity utilization
Read
performance
Write
performance
Built-in spare
drive
RAID level-0
No
100%
Superior
Superior
No
RAID level-1
Yes
50%
Very high
Very high
No
RAID level-1E
Yes
50%
Very high
Very high
No
RAID level-5
Yes
67% to 94%
Superior
High
No
RAID level-5E
Yes
50% to 88%
Superior
High
Yes
RAID level-00
No
100%
Superior
Superior
No
RAID level-10
Yes
50%
Very high
Very high
No
RAID level-1E0
Yes
50%
Very high
Very high
No
RAID level-50
Yes
67% to 94%
Superior
High
No
Drive-state descriptions
This section provides descriptions of the physical and logical drive states.
ServeRAID publications frequently refer to these states during instructions and
procedures.
Physical drive-state descriptions
The following table provides descriptions of the valid physical drive states.
Drive state
Meaning
Defunct
A physical drive in the online, hot-spare, or rebuild state has become defunct. It does not
respond to commands, which means that the ServeRAID controller cannot communicate
properly with the drive.
If a physical drive has become defunct, refer to “Rebuilding a defunct drive” on page 147.
Hot spare
A hot-spare drive is a physical drive that is defined for automatic use when a similar drive
fails.
Online
The drive is online. It is functioning properly and is part of an array.
Rebuilding
The drive is being rebuilt.
For more information on rebuilding a drive, refer to “Rebuilding a defunct drive” on page 147.
Ready
The ServeRAID controller recognizes a ready drive as being available for definition.
Standby hot spare
A standby hot spare is a hot-spare drive that the ServeRAID controller has spun down. If an
online drive becomes defunct and no suitable hot-spare drive is available, a standby
hot-spare drive of the appropriate size automatically spins up, and enters the rebuild state.
1. Disk utilization, read, and write performance depend on the number of drives in the array. Generally, the more drives in the array,
the better your performance.
24
IBM
®
User’s Reference: ServeRAID
™
-4 Ultra160 SCSI Controller
Содержание ServeRAID-4 Ultra160 Series
Страница 1: ...IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller SC25 P258 10...
Страница 2: ......
Страница 3: ...IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller SC25 P258 10...
Страница 12: ...x IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Страница 18: ...xvi IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Страница 19: ...Part 1 Installation and configuration Copyright IBM Corp 2001 1...
Страница 20: ...2 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Страница 32: ...14 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Страница 44: ...26 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Страница 58: ...40 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Страница 60: ...42 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Страница 69: ...Part 2 Utility programs Copyright IBM Corp 2001 51...
Страница 70: ...52 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Страница 74: ...56 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Страница 96: ...78 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Страница 107: ...Part 3 Installing the IBM ServeRAID Cluster Solution Copyright IBM Corp 2001 89...
Страница 108: ...90 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Страница 112: ...94 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Страница 116: ...98 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Страница 124: ...106 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Страница 140: ...122 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Страница 146: ...128 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Страница 147: ...Part 4 Maintenance and troubleshooting Copyright IBM Corp 2001 129...
Страница 148: ...130 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Страница 150: ...132 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Страница 152: ...134 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Страница 184: ...166 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Страница 185: ...Part 5 Appendixes Copyright IBM Corp 2001 167...
Страница 186: ...168 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Страница 200: ...182 IBM User s Reference ServeRAID 4 Ultra160 SCSI Controller...
Страница 207: ......