A
B
C
7.
If reusing original Dexerials TIM, perform the following step
a.
Using tweezers, move the TIM from the ESD surface to the new system processor module.
8.
If installing new Indium, Hitachi or Dexerials TIM, perform the following steps
Note:
There could be three types of TIM pads in the FRU replacement kit - Indium TIM pad (part
no. 00FW781) (B) , Hitachi TIM pad (part no. 00E7418) (C), Dexerials TIM pad (part no. 01AF742)
(D)
.
a.
If the TIM or heat sink replacement is necessary, use P/N 01AF159 Heat sink and TIM.
b.
Open the TIM packaging and carefully remove the TIM, holding by the edges of the carrier strip
and holding it away from the shipping container.
c.
Remove the protective film from the clear carrier strip by using the supplied tweezers.
Note:
The TIM must remain flat. Small wrinkles are acceptable, but folds are not acceptable.
d.
Using the tweezers, remove the TIM from the carrier strip. In the case of a Hitachi TIM pad,
center it onto the SCM with the black side up. In the case of an Indium TIM pad, center it on the
SCM with the red stripe facing up. The gray colored Dexerials TIM can be placed with any side
facing up. Align the beveled corners and the SCM (A).
Install SCM
25
Содержание SCM
Страница 1: ...Power Systems SCM IBM ...
Страница 2: ......
Страница 3: ...Power Systems SCM IBM ...
Страница 4: ...ii Power Systems SCM ...
Страница 22: ...18 Power Systems SCM ...
Страница 52: ...48 Power Systems SCM ...
Страница 53: ......
Страница 54: ...IBM Printed in USA ...