8.
Connect the power cords to the power supplies and the power outlets.
9.
Install the chassis door as described in “Removing and installing the chassis
door” on page 81.
10.
Power on the chassis “Providing power to the SAN768B-2” on page 37. The
system performs a power-on self-test (POST). The POST takes a minimum of
three minutes and is complete when LED activity returns to standard state.
11.
Verify that the POST is complete. All power LED indicators on the port,
control processor, and core switch blades should be a steady green.
12.
Verify that all components are functioning correctly by checking their LEDs. If
the LEDs do not indicate correct operation, try reinstalling the corresponding
component.
Downloading the configuration
Once the chassis and its various components have been reassembled and powered
back on, use the
configDownload
command to restore the original configuration.
The
configDownload
command can be entered through a Telnet or serial session,
but the chassis must have an Ethernet connection to the server name or IP of the
host for the download process to complete. For more information, refer to the
help
configdownload
command or the
Fabric OS Command Reference
.
Complete the following steps to download the configuration.
1.
Log in to the chassis as
admin:
switch:admin>
login
login:
admin
password:
xxxxxxxx
switch:admin>
Note:
If you are using the Virtual Fabric feature, you should run
configdownload -vf
before running the
configdownload
command in order to
restore the logical switch configuration.
2.
Enter
configDownload
command:
switch:admin>
configdownload -all
Server Name or IP Address [host]:
123.123.123.123
User Name [None]:
Admin24
File Name [config.txt]:
config-switch.txt
Password:
xxxxxxxx
download complete
switch:admin>
3.
Reboot the system.
Verifying the correct operation of the system
Complete these steps to verify that the hardware is operating correctly.
1.
Log in to the SAN768B-2 as
admin
:
switch:admin>
login
login:
admin
password:
xxxxxxxx
switch:admin>
2.
Enter the
slotShow -m
command and verify that all the installed cards are
detected and that their status is operational (enabled).
switch:admin>
slotShow -m
Slot
Blade Type
ID
Model Name
Status
--------------------------------------------
1
SW BLADE
97
FC16-32
ENABLED
Chapter 5. Removing and installing components
125
Содержание SAN768B-2
Страница 2: ......
Страница 8: ...vi SAN768B 2 Installation Service and User Guide...
Страница 10: ...viii SAN768B 2 Installation Service and User Guide...
Страница 14: ...xii SAN768B 2 Installation Service and User Guide...
Страница 28: ...xxvi SAN768B 2 Installation Service and User Guide...
Страница 40: ...12 SAN768B 2 Installation Service and User Guide...
Страница 108: ...80 SAN768B 2 Installation Service and User Guide...
Страница 182: ...154 SAN768B 2 Installation Service and User Guide...
Страница 186: ...158 SAN768B 2 Installation Service and User Guide...
Страница 196: ...168 SAN768B 2 Installation Service and User Guide...
Страница 202: ...174 SAN768B 2 Installation Service and User Guide...
Страница 220: ...192 SAN768B 2 Installation Service and User Guide...
Страница 226: ...198 SAN768B 2 Installation Service and User Guide...
Страница 227: ......
Страница 228: ...Part Number 00MA746 Printed in USA GA32 0893 06 1P P N 00MA746...