v
A serial console connection to the active CP blade. The active CP is indicated
by an illuminated blue LED on the blade front panel.
v
A Telnet session using the chassis management IP address.
2.
Log into the device using admin as your password. If you have not changed the
default password, use password.
3.
Check the PID setting using the
configshow
command as in the following
example. You can use the| grep -i pid qualifier to pinpoint the PID information.
switch:admin> configshow | grep -i pid
fabric.ops.mode.pidFormat:1
fabric.wwnPidMode:1
The 1 indicates that the WWN-based persistent PID feature is enabled. The
default value is 0 for disabled.
4.
Set the PID mode if necessary using the
configure
command.
Refer to the "Fabric Parameters" section under the "Configure" command in the
Fabric OS Command Reference for details on configuring WWN Based persistent
PID.
Verifying installed licenses and license key
About this task
Depending on the vendor agreement, certain licenses are factory installed on the
device. Use the following steps to list installed licenses and to record your license
key and chassis ID for future reference.
Procedure
1.
Log into the device using one of the following methods:
v
A serial console connection to the active CP blade. The active CP is indicated
by an illuminated blue LED on the blade front panel.
v
A Telnet session using the chassis management IP address.
2.
Log into the device using admin as your password. If you have not changed the
default password, use password.
3.
Enter the
licenseShow
command to determine which licenses are enabled. This
will list installed licenses and display a license key, such as
aNYtMJg7tcMZrTZ9JTXBC4SXWLJMY3QfBKYHG
.
4.
Enter the
licenseIdShow
command on the active CP blade to obtain the chassis
ID. The chassis ID is required to obtain and activate licenses for the device.
5.
Record the license key and chassis ID for future reference.
What to do next
Refer to the Fabric OS Software Licensing Guide for more information.
Verifying correct operation
About this task
Perform the following steps to verify correct operation of the device.
Procedure
1.
Check the LEDs of all power supplies, fans, and blades to verify that all are
functional.
54
SAN512B-6 Installation, Service, and User Guide
Содержание SAN512B-6
Страница 2: ......
Страница 8: ...vi SAN512B 6 Installation Service and User Guide...
Страница 10: ...viii SAN512B 6 Installation Service and User Guide...
Страница 12: ...x SAN512B 6 Installation Service and User Guide...
Страница 40: ...16 SAN512B 6 Installation Service and User Guide...
Страница 60: ...36 SAN512B 6 Installation Service and User Guide...
Страница 128: ...104 SAN512B 6 Installation Service and User Guide...
Страница 140: ...116 SAN512B 6 Installation Service and User Guide...
Страница 170: ...146 SAN512B 6 Installation Service and User Guide...
Страница 184: ...160 SAN512B 6 Installation Service and User Guide...
Страница 196: ...172 SAN512B 6 Installation Service and User Guide...
Страница 208: ...184 SAN512B 6 Installation Service and User Guide...
Страница 214: ...Figure 59 Removal and replacement of the chassis door 190 SAN512B 6 Installation Service and User Guide...
Страница 258: ...234 SAN512B 6 Installation Service and User Guide...
Страница 274: ...250 SAN512B 6 Installation Service and User Guide...
Страница 285: ......
Страница 286: ...IBM Part Number 01JC152 Printed in USA SC27 8966 02 1P P N 01JC152...