v
RASlog messages may occur during periodic WWN card audit routines alerting
you of data or license mismatches between WWN cards and other errors. Some
of these messages may direct you to contact technical support or to run the
wwnrecover
command. You can use this command to further verify or to fix
problems. If an EM-1220 or EM-1222 error message occurs due to WWN card
data corruption or data mis-matches across WWN cards, data recovery may be
possible using this command. For more information on using
wwnrecover
, refer
to “Using the wwnrecover utility” on page 151. If recovery is not possible,
command output will direct you to replace the affected card(s).
v
Status LEDs on the WWN bezel do not reflect the actual status of the WWN
cards or indicate a problem. For information on interpreting LED patterns, refer
to “Interpreting WWN card LEDs” on page 78. Note that the LED patterns may
temporarily change during POST and other diagnostic tests.
v
Problems viewing or modifying the data stored on the WWN card.
v
Error messages regarding WWN units in
chassisshow
output.
Error messages that may indicate problems with a WWN card are summarized in
the following table.
Table 19. Messages that may indicate WWN card failure
Type of message
Sample error message
WWN unit fails its
field-replaceable unit (FRU)
header access.
0x24c (fabos): Switch: switchname, error
EM-I2C_TIMEOUT, 2, WWN 1 I2C
timed out: state 0x4
WWN unit fails to power
on.
<timestamp>, [EM-1004],
<sequence-number>, CRITICAL,
<system-name>, WWN # failed to power
onor<timestamp>, [EM-1043],
<sequence-number>, WARNING,
<system-name>, Can’t power <FRU Id>
<state (on or off)>.
WWN unit is being faulted.
0x24c (fabos): Switch: switchname
, Critical EM-WWN_UNKNOWN, 1, Unknown
WWN #2 is being faultedor<timestamp>,
[EM-1003], 40, SLOT 7 | FFDC | CHASSIS,
CRITICAL, Chassis, WWN 2 has unknown
hardware identifier: FRU faultedor<timestamp>,
[EM-1034], <sequence-number>, ERROR,
<system-name>, WWN # set to faulty,
rc=<return code>
WWN unit is not present
or is not accessible.
0x24c (fabos): Switch:
switchname, Error EM-WWN_ABSENT, 2,
WWN #1 not presentor<timestamp>,
[EM-1036], <sequence-number>, WARNING,
<system-name>, <FRU Id> is not
accessible.
Writing to the FRU history
log (hilSetFruHistory) has
failed.
0x24c (fabos): Switch:
switchname, Error EM-HIL_FAIL, 2,
HIL Error: hilSetFruHistory failed,
rc=-3 for SLOT 3
Chapter 10. WWN Cards
149
Содержание SAN512B-6
Страница 2: ......
Страница 8: ...vi SAN512B 6 Installation Service and User Guide...
Страница 10: ...viii SAN512B 6 Installation Service and User Guide...
Страница 12: ...x SAN512B 6 Installation Service and User Guide...
Страница 40: ...16 SAN512B 6 Installation Service and User Guide...
Страница 60: ...36 SAN512B 6 Installation Service and User Guide...
Страница 128: ...104 SAN512B 6 Installation Service and User Guide...
Страница 140: ...116 SAN512B 6 Installation Service and User Guide...
Страница 170: ...146 SAN512B 6 Installation Service and User Guide...
Страница 184: ...160 SAN512B 6 Installation Service and User Guide...
Страница 196: ...172 SAN512B 6 Installation Service and User Guide...
Страница 208: ...184 SAN512B 6 Installation Service and User Guide...
Страница 214: ...Figure 59 Removal and replacement of the chassis door 190 SAN512B 6 Installation Service and User Guide...
Страница 258: ...234 SAN512B 6 Installation Service and User Guide...
Страница 274: ...250 SAN512B 6 Installation Service and User Guide...
Страница 285: ......
Страница 286: ...IBM Part Number 01JC152 Printed in USA SC27 8966 02 1P P N 01JC152...