Note:
The
haEnable
command will cause the standby CP blade to reboot. Wait
until POST completes before moving to the next step. POST is complete when
the status LED on the CP blade returns to a steady green state.
2.
Enter
haShow
and verify that the command output includes "HA Enabled,
Heartbeat Up". If it is not yet enabled, re-enter the command until you have
verified that redundancy is achieved.
Note:
The
haEnable
command will cause the standby CP blade to reboot.
Chassis_1:admin> hashow
Local CP (Slot 2, CP1) : Active
Remote CP (Slot 1, CP0) : Standby, Healthy
HA Enabled, Heartbeat Up, HA State Synchronized
3.
Enter
firmwareShow
to verify that the firmware version has been updated and
that the versions are the same on the two CP blades.
chassis:admin> firmwareshow -v
Slot NameAppl Primary/Secondary VersionsStatus
-----------------------------------------------------------
1CP0FOSv8.0.1STANDBY
v8.0.1
2CP1FOSv8.0.1ACTIVE *
v8.0.1
3SX6FOSv8.0.1
v8.0.1
4SX6FOSv8.0.1
v8.0.1
7SX6FOSv8.0.1
v8.0.1
8SX6FOSv8.0.1
v8.0.1
If you have one or more port or extension blades in the device, the Fabric OS
automatically detects mismatches between the active CP firmware and the
blade's firmware and triggers the auto-leveling process. This auto-leveling
process automatically updates the application blade firmware to match the
active CP blade. At the end of the auto-leveling process, the active CP and
extension blades will run the same version of the firmware.
4.
Enter the
chassisEnable
command to enable all user ports in the chassis and
enable a virtual, fabric-aware chassis.
5.
Replace the chassis door. The door is required to meet EMI compliance.
6.
Pack the faulty CP blade in the packaging provided with the new CP blade,
and contact the switch supplier to determine the return procedure.
Verifying blade operation
About this task
Perform the following tasks to verify operation of new blade:
Procedure
1.
Check the LED indicators on the blade's front panel. For information on
interpreting LED patterns, refer to “Interpreting control processor blade LEDs”
on page 74.
2.
Enter the following commands and note any error conditions:
v
slotShow
- Displays the current data on each slot in the system, including
blade type, blade ID, status, model name, and power usage.
v
haShow
- Displays control processor (CP) status.
144
SAN512B-6 Installation, Service, and User Guide
Содержание SAN512B-6
Страница 2: ......
Страница 8: ...vi SAN512B 6 Installation Service and User Guide...
Страница 10: ...viii SAN512B 6 Installation Service and User Guide...
Страница 12: ...x SAN512B 6 Installation Service and User Guide...
Страница 40: ...16 SAN512B 6 Installation Service and User Guide...
Страница 60: ...36 SAN512B 6 Installation Service and User Guide...
Страница 128: ...104 SAN512B 6 Installation Service and User Guide...
Страница 140: ...116 SAN512B 6 Installation Service and User Guide...
Страница 170: ...146 SAN512B 6 Installation Service and User Guide...
Страница 184: ...160 SAN512B 6 Installation Service and User Guide...
Страница 196: ...172 SAN512B 6 Installation Service and User Guide...
Страница 208: ...184 SAN512B 6 Installation Service and User Guide...
Страница 214: ...Figure 59 Removal and replacement of the chassis door 190 SAN512B 6 Installation Service and User Guide...
Страница 258: ...234 SAN512B 6 Installation Service and User Guide...
Страница 274: ...250 SAN512B 6 Installation Service and User Guide...
Страница 285: ......
Страница 286: ...IBM Part Number 01JC152 Printed in USA SC27 8966 02 1P P N 01JC152...