background image

Table 12. SFP+ Fibre Channel Transceivers (continued)

SFP+

Transceiver description

Type

FC16G-LW

4/8/16-Gbps Fibre Channel LW,
SFP+, LC

Long Wavelength

FC8G-SW

2/4/8-Gbps Fibre Channel SW,
SFP+, LC

Short Wavelength

FC8G-LW

2/4/8-Gbps Fibre Channel LW,
SFP+, LC

Long Wavelength

General specifications for 16-Gbps fibre channel SFP+
transceivers

Table 13. Power requirements specifications for a 16 Gbps fibre channel SFP= transceivers

SFP+

Wavelength
(nanometer)- Fibre Type

Core size
(micron)

Baud Rate
(GBd)

Cable
Distance
(meter)

FC16G-SW

850

MMF

62.5

14025

150 m

FC16G-LW

1310

SMF

G.652

14025

6.2 miles (10
km)

Environmental and Power Requirements for the 16-Gbps Fibre
Channel SFP+ Transceivers

Table 14. Power requirements specifications for a 16 Gbps fibre channel SFP+ transceivers

SFP+

Average Transmit
Power (dBm)

Average Transmit
Power (dBm)

Fibre loss budget (dBm)

Maximum Minimum Maximum Minimum

FC16G-SW

-1.3

-9 (4
Gbps)
-8.2 (8
Gbps)
-7.8
(16Gbps)

0

-

12

12

12

FC16G-LW

1.3

-9 (4
Gbps)
-8.2 (8
Gbps)
-7.8
(16Gbps)

0

12

12

12

Table 15. Environmental requirements specifications for a 16 Gbps fibre channel SFP=
transceivers

SFP+

Operating

Storage

Maximum

Minimum

Maximum

Minimum

FC16G-SW

40°F

0°F

85°F

-40°F

FC16G-LW

40°F

-0°F

85°F

-40°F

Appendix A. Product specifications

45

Содержание SAN50C-R

Страница 1: ...IBM Storage Networking SAN50C R Installation Service and User Guide SC27 9274 00 IBM...

Страница 2: ......

Страница 3: ...IBM Storage Networking SAN50C R Installation Service and User Guide SC27 9274 00 IBM...

Страница 4: ...the information in this publication be sure to read the general information under Notices on page 51 Edition notice This edition applies to the IBM SAN50C R Switch and to all subsequent releases and m...

Страница 5: ...ets 31 Installing the Switch on the Shelf Brackets 31 Installing the Shelf Bracket Kit into a Four Post EIA Rack 31 Installing the Switch on the Rack Mount Support Brackets 33 Installing the Switch on...

Страница 6: ...Russia Electromagnetic Interference Class A Statement 58 Index 59 iv SAN50C R Installation Service and User Guide...

Страница 7: ...ew Fan Bays and PSU Bays 6 7 IBM SAN50C R Fan Module 7 8 IBM SAN50C R Switch Front View LEDs 8 9 IBM SAN50C R Switch 300W AC Power Supply 9 10 IBM SAN50C R Switch PSU 10 11 Connecting an ATS for power...

Страница 8: ...vi SAN50C R Installation Service and User Guide...

Страница 9: ...ers 45 14 Power requirements specifications for a 16 Gbps fibre channel SFP transceivers 45 15 Environmental requirements specifications for a 16 Gbps fibre channel SFP transceivers 45 16 Power requir...

Страница 10: ...viii SAN50C R Installation Service and User Guide...

Страница 11: ...78 For support outside the United States you can find the service number at http www ibm com planetwide Accessibility features Accessibility features help users who have a disability such as restricte...

Страница 12: ...d your comments Your feedback is important in helping us provide the most accurate and high quality information If you have comments or suggestions for improving this document send us your comments by...

Страница 13: ...s of the danger caution and attention notices in the sections that follow v Note These notices provide important tips guidance or advice v Attention notices on page xvii These notices indicate potenti...

Страница 14: ...the following caution notices before installing or servicing this device CAUTION Energy hazard present Shorting may result in system outage and possible physical injury Remove all metallic jewelry bef...

Страница 15: ...e ensure that all connections to dc power are disconnected at the dc power input terminals C031 CAUTION Servicing of this product or unit is to be performed by trained service personnel only C032 CAUT...

Страница 16: ...ld place dangerous voltage on the metal shell If any of the conditions are not as described STOP Ensure the improper voltage or impedance conditions are corrected before proceeding D003 DANGER An elec...

Страница 17: ...one hand only to connect or disconnect signal cables v Never turn on any equipment when there is evidence of fire water or structural damage v Disconnect the attached power cords telecommunications sy...

Страница 18: ...nsible for using professional movers riggers in the case of equipment relocation or disposal DANGER Heavy equipment personal injury or equipment damage might result if mishandled D006 Safety labels As...

Страница 19: ...ility of damage to a program device or system or to data An exclamation point symbol may accompany an attention notice but is not required A sample attention notice follows Attention Do not bend a fib...

Страница 20: ...due to uneven mechanical loading always install the heaviest devices in the bottom of the rack cabinet Always install servers and optional devices starting from the bottom of the rack cabinet v Rack...

Страница 21: ...provide the correct power connection to a rack refer to the rating labels located on the equipment in the rack to determine the total power requirement of the supply circuit v For sliding drawers Do n...

Страница 22: ...st 760 x 2030 mm 30 x 80 in Ensure that all devices shelves drawers doors and cables are secure Ensure that the four leveling pads are raised to their highest position Ensure that there is no stabiliz...

Страница 23: ...of the Cisco documents such as the Fabric Configuration Guide you will notice that the model numbers reflect the corresponding Cisco products Table 1 provides a product matrix to correlate the Cisco...

Страница 24: ...xxii SAN50C R Installation Service and User Guide...

Страница 25: ...C R Switch can be deployed in the existing native Fibre Channel networks which ensures protection of your investments in storage networks Two 1 10 Gbps ports support Small Computer System Interface ov...

Страница 26: ...it includes 40 integrated 16 Gbps Fibre Channel switching ports and eight 10 Gbps Ethernet Fibre Channel over Ethernet FCoE port modules The IBM IBM SAN50C R integrated supervisor module has a PowerPC...

Страница 27: ...it includes 40 integrated 16 Gbps Fibre Channel switching ports and eight 10 Gbps Ethernet Fibre Channel over Ethernet FCoE port modules The IBM SAN50C R integrated supervisor module has a PowerPC 857...

Страница 28: ...10G iSCSI FC Ports 7 STATUS LED 3 FCoE Ports 8 P S LED 4 Fibre Channel Ports 9 FAN LED 5 MGMT ETH Port 10 CONSOLE Port The LEDs on the supervisor module indicate the status of the supervisor module p...

Страница 29: ...ring environmental monitoring v The module is not operational because a fault occurred during the initialization sequence Red The power is on but it did not boot up the Diag or iSAN image P S Green Po...

Страница 30: ...R Switch has two fan trays that are installed vertically at the back of the chassis Each fan module can be removed while the other fan module continues to move air through the chassis rav00061 5 4 3...

Страница 31: ...rav00052 Figure 7 IBM SAN50C R Fan Module Chapter 1 Introducing the SAN50C R 7...

Страница 32: ...alarms from ASIC when the temperature exceeds the threshold At 104 F 40 C or less a single fan tray can be removed and the system can continue to operate long enough to allow for replacement of a fail...

Страница 33: ...The following figure shows a fan blank module rav00051 Figure 9 IBM SAN50C R Switch 300W AC Power Supply Chapter 1 Introducing the SAN50C R 9...

Страница 34: ...Each PSU can provide information about itself to the supervisor The two types of information available are status information output voltage fan state unit state Figure 10 IBM SAN50C R Switch PSU 10 S...

Страница 35: ...SUs remain functional one through the ATS and the other directly connected to the other grid The APC AP7721 has been verified to work with the IBM SAN50C R switch If insufficient power is available to...

Страница 36: ...SM DDM 13 dB 40 km v 4 8 16 Gbps Fibre Channel FICON LW SFP DWDM SM DDM 1550nm 13 dB 40 km v 2 4 8 Gbps Fibre Channel LW SFP DWDM SM DDM 80 km v 2 4 8 Gbps Fibre Channel LW SFP CWDM SM DDM 23dB 70 km...

Страница 37: ...y through the use of a special tool lock and key or other means of security DANGER Only trained and qualified personnel should be allowed to install replace or service this equipment DANGER A readily...

Страница 38: ...re the following facilities requirements are met Table 3 Facility requirements Type Requirements Electrical v Adequate supply circuit line fusing and wire size as specified by the electrical rating on...

Страница 39: ...R Switch can be installed using the following methods v In an open EIA rack The rack mount kit shipped with the switch The Telco and EIA Shelf Bracket Kit an optional kit purchased separately in addi...

Страница 40: ...s on page 43 section If available you can use an uninterruptible power supply UPS to protect against power failures CAUTION Avoid UPS types that use ferro resonant technology These UPS types can becom...

Страница 41: ...2 per kit M4 X 6 mm Phillips flat head screws 8 per kit 12 24 X 3 4 inch Phillips binder head screws 8 per kit 10 32 x 3 4 inch Phillips binder head screws 8 per kit Cable Management Bracket Kit Cable...

Страница 42: ...llows a Attach the bracket to the switch with the two M3 screws originally provided with the bracket 3 Install the slider rails in the rack Position one of the slider rails against the rack mounting r...

Страница 43: ...hat the rails are horizontal and at the same height 5 Insert the switch into the rack as follows a Figure 1 4 Installing the Slider Rails a Use both hands to position the switch with the back of the s...

Страница 44: ...lled on either side Grounding the system This section describes the need for system grounding and explains how to prevent damage from electrostatic discharge Note In all situations grounding practices...

Страница 45: ...o that any built up static charge is then safely dissipated to the entire rack 3 Plug the strap into the port and alternatively clip an alligator clip onto the grounding lug screws by attaching either...

Страница 46: ...connection with any other rack or system power ground connections that you make The system ground connection is required if this equipment is installed in a U S or European Central Office v You must c...

Страница 47: ...nit you may need the optional jumper power cord to connect the IBM SAN50C R switch to your outlet receptacle 4 Connect the other end of the power cable to a power source 5 Ensure that the switch is ad...

Страница 48: ...ll does not operate correctly contact your customer service representative for a replacement 5 Verify that the system software has booted and the switch has initialized without error messages If any p...

Страница 49: ...he power cable into the power supply and place the cable retention device to ensure that the cable cannot be pulled out 6 Connect the other end of the power cable to an AC power source 7 Turn the powe...

Страница 50: ...tches will shut down sooner if the major temperature threshold is exceeded To remove an existing fan module follow these steps Procedure 1 Loosen the four captive screws on the module being removed 2...

Страница 51: ...t the Fan STATUS LED is green If the LED is not green one or more fans are faulty If this occurs contact your customer service representative for a replacement part Chapter 2 Installing the IBM SAN50C...

Страница 52: ...28 SAN50C R Installation Service and User Guide...

Страница 53: ...ctions on how to install the rack mount kit see the Installing the Switch section General Requirements for Racks The rack must be one of the following types v Standard 19 inch four post EIA rack with...

Страница 54: ...e level Rack Mounting Guidelines CAUTION If the rack is on wheels ensure that the brakes are engaged or the rack is otherwise stabilized If installing this kit in an EIA rack attach the switch to all...

Страница 55: ...install and remove brackets Before installing the shelf brackets check the contents of your kit against the items in the following table Table 7 Contents of Shelf Bracket Kit Quantity Part Description...

Страница 56: ...The bottom hole of the shelf bracket should align with the bottom hole of a rack unit on the rack mounting rail the hole immediately above the 1 2 in spacing 2 Repeat with the other shelf bracket 3 Ve...

Страница 57: ...personnel should be allowed to install replace or service this equipment Note Note Before you install operate or service the system see the IBM Systems Environmental Notices and User Guide Z125 5823 f...

Страница 58: ...helf brackets are at the same height using the level or tape measure as desired Installing the Switch on the Shelf Brackets This section provides general instructions for installing the IBM SAN50C R s...

Страница 59: ...C R switch to the rack mounting rails Slide the clip nuts over the holes on the non threaded rails on the rack These clip nuts provide the threading for the screws that will secure the chassis to the...

Страница 60: ...36 SAN50C R Installation Service and User Guide...

Страница 61: ...hat are used to connect to the SAN or for in band management The FC ports on IBM SAN50C R switch support the IBM FICON connectivity v IP Storage ports IP Storage Services ports that are used for the F...

Страница 62: ...rminal emulation The terminal emulation software frequently an application such as HyperTerminal or Procomm Plus makes communication between the switch and computer possible during setup and configura...

Страница 63: ...ease notes Note Class 1 laser product Note Invisible laser radiation may be emitted from disconnected fibers or connectors Do not stare into beams or view directly with optical instruments CAUTION Wea...

Страница 64: ...rrect position before continuing 3 Remove the transceiver from the port v If the transceiver has a Mylar tab latch gently pull the tab straight out do not twist and then pull the transceiver out of th...

Страница 65: ...d of the transceiver 4 Align the cable connector with the transceiver and insert the connector into the transceiver until it clicks into place v If the transceiver has a Mylar tab orient the transceiv...

Страница 66: ...revent ESD damage wear an ESD preventive wrist strap that is connected to the chassis v Do not remove and reinsert a transceiver more often than necessary Repeated removals and insertions can shorten...

Страница 67: ...ting and storage 5 to 95 Altitude certified for operation 197 to 6500 ft 60 to 2000 m Altitude designed and tested for operation 200 to 10 000 ft 60 to 3000 m Table 9 Physical specifications for the I...

Страница 68: ...onnection guidelines The IBM SAN50C R switch is compatible with Cisco SFP transceivers and cables that have LC connectors The wavelength of each transceiver must match the transceiver on the other end...

Страница 69: ...SW 850 MMF 62 5 14025 150 m FC16G LW 1310 SMF G 652 14025 6 2 miles 10 km Environmental and Power Requirements for the 16 Gbps Fibre Channel SFP Transceivers Table 14 Power requirements specifications...

Страница 70: ...ansceivers SFP Average Transmit Power dBm Average Receive Power dBm Fibre loss budget dBm Maximum Minimum Maximum Minimum FC10G SW 1 3 7 3 1 0 9 9 7 3 FC10G LW 0 5 8 2 1 0 9 9 7 4 Table 18 Environment...

Страница 71: ...LW 3 2 Gbps 1 4 Gbps 0 5 8 Gbps 11 7 2 Gbps 8 4 4 Gbps 8 4 8 Gbps 3 2 Gbps 1 4 Gbps 0 5 8 Gbps 7 8 2 Gbps 7 8 4 Gbps 6 4 8 Gbps Table 21 Environmental requirements specifications for a 8 Gbps fibre c...

Страница 72: ...48 SAN50C R Installation Service and User Guide...

Страница 73: ...sible v Date you received the switch v Chassis serial number See the Finding the Chassis Serial Number v Type of software and release number v Maintenance agreement or warranty information v Brief des...

Страница 74: ...50 SAN50C R Installation Service and User Guide...

Страница 75: ...ocal law INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON I...

Страница 76: ...n atwww ibm com legal copytrade shtml Adobe the Adobe logo PostScript and the PostScript logo are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States and or o...

Страница 77: ...harmful interference and 2 this device must accept any interference received including interference that might cause undesired operation Industry Canada Compliance Statement This Class A digital appar...

Страница 78: ...gen verursachen in diesem Fall kann vom Betreiber verlangt werden angemessene Ma nahmen zu ergreifen und daf r aufzukommen Deutschland Einhaltung des Gesetzes ber die elektromagnetische Vertr glichkei...

Страница 79: ...s ber die elektromagnetische Vertr glichkeit von Ger ten Dieses Produkt entspricht dem Gesetz ber die elektromagnetische Vertr glichkeit von Ger ten EMVG Dies ist die Umsetzung der EU Richtlinie 2014...

Страница 80: ...formation for Taiwan IBM Taiwan Product Service Contact Information IBM Taiwan Corporation 3F No 7 Song Ren Rd Taipei Taiwan Tel 0800 016 888 Japan Voluntary Control Council for Interference Class A S...

Страница 81: ...on Technology Industries Association JEITA statement for products less than or equal to 20 A per phase This statement explains the JEITA statement for products greater than 20 A single phase This stat...

Страница 82: ...Russia Electromagnetic Interference Class A Statement This statement explains the Russia Electromagnetic Interference EMI statement 58 SAN50C R Installation Service and User Guide...

Страница 83: ...ience xxi L labels safety xvi license for patents 51 M memory specifications 43 N notices attention xvii caution xi danger xiii environmental xi xx general 51 IBM 51 patents 51 safety xi types xi noti...

Страница 84: ...60 SAN50C R Installation Service and User Guide...

Страница 85: ......

Страница 86: ...IBM Printed in USA SC27 9274 00...

Отзывы: