Table
11.
Facility
requirements
(continued)
Type
Requirements
Thermal
v
Air
flows
from
the
non-port
side
to
the
port
side.
A
minimum
air
flow
of
47
cubic
feet/minute
(79.8
cubic
meters/hour)
available
in
the
immediate
vicinity
of
the
switch.
v
Ambient
air
temperature
not
exceeding
40°
C
(104°
F)
while
the
switch
is
operating
v
At
a
minimum,
adequate
cooling
requires
that
you
install
the
switch
with
the
nonport
side,
which
contains
the
air
intake
vents,
facing
the
cool-air
aisle
v
All
equipment
in
the
rack
should
force
air
in
the
same
direction
to
avoid
intaking
exhaust
air
v
Ensure
that
airflow
and
temperature
requirements
are
met
on
an
ongoing
basis,
particularly
if
the
switch
is
installed
in
a
closed
or
multicabinet
assembly
Cabinet
(when
rack-mounted)
v
One
rack
unit
in
a
standard
EIA
48.3
cm
(19-in.)
cabinet
v
All
equipment
in
cabinet
grounded
through
a
reliable
branch
circuit
connection
and
maintain
ground
at
all
times.
Do
not
rely
on
a
secondary
connection
to
a
branch
circuit,
such
as
a
power
strip
v
Additional
weight
of
switch
must
not
exceed
the
cabinet’s
weight
limits
v
The
cabinet
must
be
secured
to
ensure
stability
in
case
of
unexpected
movement,
such
as
an
earthquake
Environmental
requirements
Table
12
lists
the
acceptable
environment
for
both
operating
and
nonoperating
conditions.
Table
12.
Environmental
requirements
Condition
Acceptable
range
during
operation
Acceptable
range
during
non-operation
Temperature
0°
to
40°
C
(32°
to
104°
F)
-25°
to
70°C
(-13°
to
158°F)
Humidity
10%
to
85%
RH
noncondensing,
at
40°C
(104°
F),
with
maximum
gradient
of
10%
per
hour
10%
to
90%
RH
noncondensing,
at
70°
C
(158°
F)
Altitude
0
to
3
km
(9,842
ft)
above
sea
level
0
to
12
km
(39,370
ft)
above
sea
level
Shock
20
G,
6
ms
duration,
half
sine
wave
33
G,
11
ms
duration,
half
sine
Vibration
0.5
G,
0.4
grms
random,
5–500
Hz
2.0
G,
1.1
grms
random,
5–500
Hz
36
SAN40B-4
Installation,
Service,
and
User’s
Guide
Содержание SAN40B-4 - System Storage Switch
Страница 2: ......
Страница 8: ...vi SAN40B 4 Installation Service and User s Guide...
Страница 10: ...viii SAN40B 4 Installation Service and User s Guide...
Страница 24: ...xxii SAN40B 4 Installation Service and User s Guide...
Страница 44: ...20 SAN40B 4 Installation Service and User s Guide...
Страница 64: ...40 SAN40B 4 Installation Service and User s Guide...
Страница 77: ......
Страница 78: ...Part Number 45W0859 Printed in USA GA32 0581 00 1P P N 45W0859...