5 CP1
FOS
v7.0.1
ACTIVE *
v7.0.1
7 FX8-24
FOS
v7.0.1
v7.0.1
If you have one or more application blades in the chassis, the Fabric OS
automatically detects mismatches between the active CP firmware and the
application blade's firmware and triggers the auto-leveling process. This
auto-leveling process automatically updates the application blade firmware to
match the active CP. At the end of the auto-leveling process, the active CP and
the application blades will run the same version of the firmware.
4.
Pack the faulty CP blade in the packaging provided with the new CP blade for
return to IBM, following local procedures.
5.
Install the chassis door (See “Removing and installing the chassis door” on
page 67.)
Removing and installing a CR16-4 core switch blade
This section describes how to remove and install a core switch blade. The
SAN384B-2 has two core switch blades: one in slot 3 and one in slot 6. Note that
the blade shown in Figure 36 on page 83 is shown with EMI plugs installed.
Verifying the necessity of replacement
Confirm that you need to replace the core switch blade before continuing. The
following events might indicate that a core switch blade is faulty:
v
The status LED on the core switch blade is lit steady amber, or the power LED is
not lit.
v
The
slotShow
command does not show that the core switch blade is enabled.
v
The
haShow
command indicates an error.
v
Any of the following messages display in the error log:
– “Slot unknown” message relating to a core switch blade slot
– core switch blade errors or I
2
C timeouts
– FRU: FRU_FAULTY messages for a core switch blade
– Configuration loader messages or “Sys PCI config” messages
– Generic system driver messages (“FABSYS”)
– Platform system driver messages (“Platform”)
– Error messages that indicate a problem with a core switch blade
– Function fail messages for the core switch blade master
For more information about error messages, refer to the
Fabric OS Message
Reference
.
Time and items required
The installation procedure for the core switch blade takes approximately 30
minutes. The following items are required for the core switch blade replacement:
v
ESD grounding strap
v
#2 Phillips screwdriver
v
Replacement CR16-4 core switch blade.
82
SAN384B-2 Installation, Service, and User Guide
Содержание SAN384B-2
Страница 2: ......
Страница 8: ...vi SAN384B 2 Installation Service and User Guide ...
Страница 12: ...x SAN384B 2 Installation Service and User Guide ...
Страница 14: ...xii SAN384B 2 Installation Service and User Guide ...
Страница 16: ...xiv SAN384B 2 Installation Service and User Guide ...
Страница 28: ...xxvi SAN384B 2 Installation Service and User Guide ...
Страница 32: ...xxx SAN384B 2 Installation Service and User Guide ...
Страница 82: ...50 SAN384B 2 Installation Service and User Guide ...
Страница 146: ...114 SAN384B 2 Installation Service and User Guide ...
Страница 172: ...140 SAN384B 2 Installation Service and User Guide ...
Страница 182: ...Taiwan Class A Electronic Emission Statement 150 SAN384B 2 Installation Service and User Guide ...
Страница 187: ...WWN bezel 65 card status 65 WWN bezel installing 88 removing 88 WWN card failure 65 removing 88 Index 155 ...
Страница 188: ...156 SAN384B 2 Installation Service and User Guide ...
Страница 189: ......
Страница 190: ... Part Number 98Y2654 Printed in USA GA32 0894 03 1P P N 98Y2654 ...