8.
Remove the power backplane from the node.
Replacing the power backplane
The power backplane might have to be replaced for a service action.
Replacing the SAN Volume Controller 2145-8G4 power backplane
This topic describes how to replace the SAN Volume Controller 2145-8G4 power backplane.
Take precautions to avoid damage from static electricity. Wear an anti-static wrist strap and use a
static-protected mat or surface. For more information, see “Handling static-sensitive devices” on page xx.
Perform the following steps to replace the power backplane:
1.
Align the keyhole slots in the power-supply backplane with the mounting pins in the node.
2.
Slide the power-supply backplane toward the right side of the node until the edge-connectors are
fully connected.
3.
Reconnect the cables to the power-supply backplane.
4.
Install the power supply into the power-supply bay as shown in Figure 166 on page 174.
1
svc001
13
Figure 165. SAN Volume Controller 2145-8F4 or SAN Volume Controller 2145-8F2 power backplane
Chapter 2. Removing and replacing parts
173
Содержание SAN Volume Controller 2145-CG8
Страница 1: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Страница 2: ......
Страница 3: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Страница 14: ...xii IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 24: ...xxii IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 30: ...xxviii IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 54: ...24 IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 362: ...332 IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 364: ...334 IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 371: ......
Страница 372: ...Part Number 31P1584 Printed in USA GC27 2283 00 1P P N 31P1584...