2.
Replace the top cover. See “Replacing the top cover” on page 81.
3.
Place the node in the rack. See “Replacing the SAN Volume Controller in a rack” on page 55.
4.
If there is a problem restarting the node, see MAP 5900 in the
IBM System Storage SAN Volume
Controller Troubleshooting Guide
; then connect a monitor and keyboard to the system and reset the BIOS
date and time.
Removing the power supply
You must remove the SAN Volume Controller power supply if you intend to replace it.
Use the reference numbers in parentheses at the end of each notice, such as (C003) for example, to find
the matching translated notice in
IBM System Storage SAN Volume Controller Safety Notices
.
svc001
12
Figure 147. CMOS battery socket
Chapter 2. Removing and replacing parts
155
|
|
|
|
|