Note:
The
2145
uninterruptible
power
supply-1U
(2145
UPS-1U)
does
not
power
off
when
the
SAN
Volume
Controller
is
shut
down
from
the
power
button.
Check
LED
The
amber
check
LED
is
used
to
indicate
critical
failures
on
the
service
controller.
If
the
check
LED
is
off
and
the
power
LED
is
on,
the
service
controller
is
working
correctly.
If
the
check
LED
is
on,
a
critical
service
controller
failure
was
detected.
The
check
LED
is
also
on
while
the
service
controller
code
is
being
reprogrammed.
For
example,
when
the
SAN
Volume
Controller
cluster
code
is
being
upgraded,
the
check
LED
is
on.
It
is
normal
for
the
power
LED
to
be
on
at
this
time.
Operator
information
panel
The
operator
information
panel
contains
indicators
and
buttons
for
the
SAN
Volume
Controller
2145-8F2
or
SAN
Volume
Controller
2145-8F4.
1
Release
latch
for
light
path
diagram
2
System-error
LED
(amber)
3
Information
LED
(amber)
4
Location
LED
(blue)
5
Hard
disk
drive
activity
LED
(green)
6
Power
control
button
7
Power
LED
(green)
8
USB
connector
Release
latch
The
release
latch
gives
you
access
to
the
light
path
diagnostics
panel,
which
provides
a
preliminary
method
of
determining
the
location
of
a
problem.
After
pressing
the
release
latch
on
the
information
panel,
you
can
slide
the
light
path
diagnostics
panel
out
to
view
the
lit
LEDs.
The
LEDs
indicate
the
type
of
error
that
has
occurred.
Light
path
diagnostics
are
described
in
more
detail
in
the
light
path
maintenance
analysis
procedure
(MAP).
To
retract
the
panel,
push
it
back
into
the
node
and
snap
it
into
place.
5
6
7
8
1
2
3
4
svc00084
Figure
10.
Operator
information
panel
Chapter
1.
SAN
Volume
Controller
overview
9
|
Содержание SAN Volume Controller 2145-8F4
Страница 1: ...IBM System Storage SAN Volume Controller Installation Guide V ersion 4 1 0 GC26 7900 00...
Страница 2: ......
Страница 3: ...IBM System Storage SAN Volume Controller Installation Guide V ersion 4 1 0 GC26 7900 00...
Страница 8: ...vi IBM System Storage SAN Volume Controller Installation Guide...
Страница 74: ...44 IBM System Storage SAN Volume Controller Installation Guide...
Страница 78: ...48 IBM System Storage SAN Volume Controller Installation Guide...
Страница 120: ...90 IBM System Storage SAN Volume Controller Installation Guide...
Страница 122: ...92 IBM System Storage SAN Volume Controller Installation Guide...
Страница 128: ...98 IBM System Storage SAN Volume Controller Installation Guide...
Страница 134: ...104 IBM System Storage SAN Volume Controller Installation Guide...
Страница 138: ...108 IBM System Storage SAN Volume Controller Installation Guide...
Страница 141: ......
Страница 142: ...Part Number 31P0797 Printed in USA GC26 7900 00 1P P N 31P0797...
Страница 143: ...Spine information IBM System Storage SAN Volume Controller Installation Guide Version 4 1 0...