v
An indication that you cannot activate the system attention LED.
6.
Select one of the logical partitions in the lower table, and select
Deactivate partition LED
from the
Partition Operations
menu. A confirmation window is displayed that provides the following
information:
v
A verification that the logical partition LED was deactivated.
v
An indication that there still might be open problems within the logical partition.
v
An indication that you cannot activate the logical partition LED.
To deactivate a system attention LED by using the SDMC, complete the following steps:
1.
On the
Welcome
page, under the
Resources
tab, select the server.
2.
Click
Actions
>
Service and Support
>
Hardware
>
System Attention LED
.
3.
Click
OK
.
Activating or deactivating an identify LED by using the management
console
You can activate or deactivate an identify LED for components attached to the system from the Hardware
Management Console (HMC) or from the IBM Systems Director Management Console (SDMC).
The system provides several LEDs that help identify various components in the system, such as
enclosures or field-replaceable units (FRUs). For this reason, they are called
identify LEDs
.
You can activate or deactivate the following types of identify LEDs:
v
Identify LED for an enclosure
. If you want to add an adapter to a specific drawer (enclosure), you
need to know the machine type, model, and serial number (MTMS) of the drawer. To determine
whether you have the correct MTMS for the drawer that needs the new adapter, you can activate the
LED for a drawer and verify that the MTMS corresponds to the drawer that requires the new adapter.
v
Identify LED for a FRU associated with a specified enclosure
. If you want to hook up a cable to a
specific I/O adapter, you can activate the LED for the adapter, which is a field replaceable unit (FRU),
and then physically check to see where you should connect the cable. This is especially useful when
you have several adapters with open ports.
To activate or deactivate an identify LED for an enclosure or FRU by using the HMC, follow these steps:
1.
In the navigation area, open
Systems management
.
2.
Select the server you are working on.
3.
Click
Operations
>
LED Status
>
Identify LED
. The Identify LED, Select Enclosure window opens.
4.
To activate or deactivate an identify LED for an enclosure, select an enclosure from the table, and click
either
Activate LED
or
Deactivate LED
. The associated LED is either turned on or off.
5.
To activate or deactivate an identify LED for a FRU, select an enclosure from the table, and then select
Selected
>
List FRUs
.
6.
Select one or more FRUs from the table, and click either
Activate LED
or
Deactivate LED
. The
associated LED is either turned on or off.
To activate or deactivate an identify LED for an enclosure or FRU by using the SDMC, complete these
steps:
1.
On the
Welcome
page, under the
Resources
tab, select the server.
2.
Click
Actions
>
Service and Support
>
Hardware
>
Identify LED
.
3.
To activate or deactivate an identify LED for an enclosure, select an enclosure from the table, and click
either
Activate LED
or
Deactivate LED
. The associated LED is either turned on or off.
4.
To activate or deactivate an identify LED for a FRU, select an enclosure from the table, and then click
List FRUs
.
Common service procedures
155
Содержание Power System POWER7 Series
Страница 1: ...Power Systems Common service procedures...
Страница 2: ......
Страница 3: ...Power Systems Common service procedures...
Страница 8: ...vi...
Страница 125: ...Figure 48 Lift up on the EMC shield Common service procedures 111...
Страница 139: ...Figure 60 Lift up on the EMC shield Common service procedures 125...
Страница 186: ...172...
Страница 196: ...182...
Страница 197: ......
Страница 198: ...Printed in USA...