Yes:
Continue with the next step.
No:
Go to step 14.
12.
Is the new reference code the same as the original reference code?
Yes:
Continue with the next step.
No:
A new symptom might have occurred. Go to the Start of call procedure to determine the
cause of the problem.
This ends the procedure.
13.
Are there any other failing items that need to be replaced?
Yes:
Replace the next failing item listed for the reference code.
This ends the procedure.
.
No:
Contact your next level of support for assistance.
This ends the procedure.
14.
Are you working with a tape device?
Yes:
Perform the verification procedures in the Service functions to verify that the problem is
corrected. After the verification test is complete, the tape device description will be set to the
failed state because a resource change was detected. Perform the following tasks:
- Vary the tape device description off and then on.
- Return the system to the customer and have the customer verify the system date and time.
Then go to Verifying the repair from the HMC.
This ends the procedure.
No:
Continue with the next step.
15.
Are you working with an IOP or an IOA?
Yes:
Use the display hardware configuration service function to check for any missing or failed
hardware:
- On the command line, enter the
STRSST
(Start System Service Tools command). If you cannot get
to SST, select DST. Do not IPL the system or partition to get to DST.
- On the Start Service Tools Sign On display, enter the user ID with the service authority and
password.
- Select
Start a service tool
>
Hardware service manager
>
Logical hardware resources
>
System
bus resources
.
- Select the function key for
Include nonreporting resources
.
- If the IOP and IOA that you just replaced is a failed or nonreporting resource, the problem has
not been fixed. Continue to the next failing item in the failing item list.
This ends the procedure.
No:
Perform the verification procedures in the Service functions topics to verify that the problem
is corrected. Resources that usually vary on automatically during an IPL, or that were previously
varied on manually, might need to be varied on again after the verification procedures are
complete. Return the system to the customer and have the customer verify the system date and
time.
This ends the procedure.
Verifying the repair in Linux
You can use this procedure to verify that a repair is complete by using the Linux operating system.
1.
Run stand-alone diagnostics from either a CD or from a Network Installation Management (NIM)
server. See Running the stand-alone diagnostics from CD-ROM.
Did you encounter any problems?
No
Reboot the operating system and continue with the close of call procedure.
Yes
If the original problem still exists, replace the field-replaceable unit (FRU) or perform the isolation procedure
that is next in the FRU list. If you have reached the end of the FRU list, contact your next level of support.
If a new problem has occurs go to Beginning problem analysis and repair the new problem.
152
Содержание Power System POWER7 Series
Страница 1: ...Power Systems Common service procedures...
Страница 2: ......
Страница 3: ...Power Systems Common service procedures...
Страница 8: ...vi...
Страница 125: ...Figure 48 Lift up on the EMC shield Common service procedures 111...
Страница 139: ...Figure 60 Lift up on the EMC shield Common service procedures 125...
Страница 186: ...172...
Страница 196: ...182...
Страница 197: ......
Страница 198: ...Printed in USA...