background image

If you are viewing this information in softcopy, the photographs and color illustrations may not appear.
The drawings and specifications contained herein shall not be reproduced in whole or in part without the

written permission of IBM.
IBM has prepared this information for use with the specific machines indicated. IBM makes no

representations that it is suitable for any other purpose.
IBM's computer systems contain mechanisms designed to reduce the possibility of undetected data

corruption or loss. This risk, however, cannot be eliminated. Users who experience unplanned outages,

system failures, power fluctuations or outages, or component failures must verify the accuracy of

operations performed and data saved or transmitted by the system at or near the time of the outage or

failure. In addition, users must establish procedures to ensure that there is independent data verification

before relying on such data in sensitive or critical operations. Users should periodically check IBM's

support websites for updated information and fixes applicable to the system and related software.

Homologation statement
This product may not be certified in your country for connection by any means whatsoever to interfaces of

public telecommunications networks. Further certification may be required by law prior to making any

such connection. Contact an IBM representative or reseller for any questions.

Accessibility features for IBM Power Systems servers

Accessibility features assist users who have a disability, such as restricted mobility or limited vision, to

use information technology content successfully.

Overview
The IBM Power Systems servers include the following major accessibility features:
• Keyboard-only operation
• Operations that use a screen reader
The IBM Power Systems servers use the latest W3C Standard, WAI-ARIA 1.0 (www.w3.org/TR/wai-aria/),

to ensure compliance with US Section 508 (www.access-board.gov/guidelines-and-standards/

communications-and-it/about-the-section-508-standards/section-508-standards) and Web Content

Accessibility Guidelines (WCAG) 2.0 (www.w3.org/TR/WCAG20/). To take advantage of accessibility

features, use the latest release of your screen reader and the latest web browser that is supported by the

IBM Power Systems servers.
The IBM Power Systems servers online product documentation in IBM Knowledge Center is enabled for

accessibility. The accessibility features of IBM Knowledge Center are described in the Accessibility

section of the IBM Knowledge Center help (www.ibm.com/support/knowledgecenter/doc/

kc_help.html#accessibility).

Keyboard navigation
This product uses standard navigation keys.

Interface information
The IBM Power Systems servers user interfaces do not have content that flashes 2 - 55 times per second.
The IBM Power Systems servers web user interface relies on cascading style sheets to render content

properly and to provide a usable experience. The application provides an equivalent way for low-vision

users to use system display settings, including high-contrast mode. You can control font size by using the

device or web browser settings.
The IBM Power Systems servers web user interface includes WAI-ARIA navigational landmarks that you

can use to quickly navigate to functional areas in the application.

16  Power Systems: Trusted platform module

Содержание Power System L922

Страница 1: ...Power Systems Trusted platform module card for the 5105 22E 9008 22L 9009 22A 9009 22G 9223 22H or 9223 22S IBM...

Страница 2: ...G229 9054 and the IBM Environmental Notices and User Guide Z125 5823 This edition applies to IBM Power Systems servers that contain the POWER9 processor and to all associated models Copyright Interna...

Страница 3: ...Removing the trusted platform module card 8 Replacing the trusted platform module card 9 Preparing the system for operation 10 Notices 15 Accessibility features for IBM Power Systems servers 16 Privac...

Страница 4: ...iv...

Страница 5: ...00 300 8751 German safety information Das Produkt ist nicht f r den Einsatz an Bildschirmarbeitspl tzen im Sinne 2 der Bildschirmarbeitsverordnung geeignet Laser safety information IBM servers can use...

Страница 6: ...isconnect 1 Turn off everything unless instructed otherwise 2 For AC power remove the power cords from the outlets 3 For racks with a DC power distribution panel PDP turn off the circuit breakers loca...

Страница 7: ...n a different rack cabinet An electrical outlet that is not correctly wired could place hazardous voltage on the metal parts of the system or the devices that attach to the system It is the responsibi...

Страница 8: ...fore the cabinet is relocated Inspect the route that you plan to take to eliminate potential hazards Verify that the route that you choose can support the weight of the loaded rack cabinet Refer to th...

Страница 9: ...position for example when working from a ladder Stability hazard The rack may tip over causing serious personal injury Before extending the rack to the installation position read the installation ins...

Страница 10: ...uct might be equipped with multiple AC power cords or multiple DC power cables To remove all hazardous voltages disconnect all power cords and power cables L003 L007 CAUTION A hot surface nearby L007...

Страница 11: ...ing into the other end of a disconnected optical fiber to verify the continuity of optic fibers may not injure the eye this procedure is potentially dangerous Therefore verifying the continuity of opt...

Страница 12: ...on off smooth platforms without appreciable force so take care not to push or lean Keep riser tilt adjustable angling platform option flat at all times except for final minor angle adjustment when nee...

Страница 13: ...itable for connection to intrabuilding or unexposed wiring or cabling only The intrabuilding ports of this equipment must not be metallically connected to the interfaces that connect to the OSP outsid...

Страница 14: ...xiv Power Systems Trusted platform module...

Страница 15: ...an HMC complete the steps in following procedures to remove and replace the TPM card Preparing the 5105 22E 9008 22L 9009 22A 9009 22G 9223 22H or 9223 22S system to remove and replace the trusted pl...

Страница 16: ...Figure 1 Removing the power cords L003 or or 2 Power Systems Trusted platform module...

Страница 17: ...ht be equipped with multiple AC power cords or multiple DC power cables To remove all hazardous voltages disconnect all power cords and power cables L003 Trusted platform module card for the 5105 22E...

Страница 18: ...the cable management arms Ensure that the cable management arms can move freely Ensure that the cables at the rear of the system do not catch or bind as you pull the system unit into the service posit...

Страница 19: ...f receiving electric shock when using or working on electrical equipment If you do not have an ESD wrist strap just prior to removing the product from ESD packaging and installing or replacing hardwar...

Страница 20: ...ss cover 8 To activate the identify LED for the faulty part press and hold push button A on the trusted platform module card as shown in the following figure Verify that the LED B is lit which indicat...

Страница 21: ...ating the identify LED 9 Look for the flashing amber LED A of the trusted platform module card See Figure 5 on page 8 Trusted platform module card for the 5105 22E 9008 22L 9009 22A 9009 22G 9223 22H...

Страница 22: ...s procedure Procedure 1 Ensure that you have the electrostatic discharge ESD wrist strap on and that the ESD clip is plugged into a ground jack or connected to an unpainted metal surface If not do so...

Страница 23: ...you have the electrostatic discharge ESD wrist strap on and that the ESD clip is plugged into a ground jack or connected to an unpainted metal surface If not do so now 2 Replace the TPM card a Insert...

Страница 24: ...and replacing the trusted platform module card complete the steps in this procedure Procedure 1 Ensure that you have the electrostatic discharge ESD wrist strap on and that the ESD clip is plugged int...

Страница 25: ...pushing them inward Ensure that the cable management arms can move freely Ensure that the cables at the rear of the unit do not catch or bind as you push the unit into the operating position Trusted p...

Страница 26: ...osition Secure the cable management arm with hook and loop fasteners around the back side of the cable management arm but not around the cables 6 Using your labels reconnect the power cords A to the s...

Страница 27: ...g a system www ibm com support knowledgecenter POWER9 p9haj crustartsys htm 10 Verify the installed part If you replaced the part because of a service action verify the installed part For instructions...

Страница 28: ...14 Power Systems Trusted platform module...

Страница 29: ...ct s and or the program s described in this publication at any time without notice Any references in this information to non IBM websites are provided for convenience only and do not in any manner ser...

Страница 30: ...sion to use information technology content successfully Overview The IBM Power Systems servers include the following major accessibility features Keyboard only operation Operations that use a screen r...

Страница 31: ...th below This Software Offering does not use cookies or other technologies to collect personally identifiable information If the configurations deployed for this Software Offering provide you as the c...

Страница 32: ...ren d rfen auch nur von der IBM empfohlene Kabel angeschlossen werden IBM bernimmt keine Verantwortung f r die Einhaltung der Schutzanforderungen wenn das Produkt ohne Zustimmung von IBM ver ndert bzw...

Страница 33: ...Technology Industries Association JEITA Notice This statement applies to products less than or equal to 20 A per phase This statement applies to products greater than 20 A single phase This statement...

Страница 34: ...ely to cause harmful interference in which case the user will be required to correct the interference at his own expense Properly shielded and grounded cables and connectors must be used in order to m...

Страница 35: ...tromagnetische Vertr glichkeit in den EU Mitgliedsstaatenund h lt die Grenzwerte der EN 55022 EN 55032 Klasse B ein Um dieses sicherzustellen sind die Ger te wie in den Handb chern beschrieben zu inst...

Страница 36: ...nformation Technology Industries Association JEITA Notice This statement applies to products less than or equal to 20 A per phase This statement applies to products greater than 20 A single phase This...

Страница 37: ...or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment Unauthorized changes or modifications could void...

Страница 38: ...t or as determined by IBM the above instructions are not being properly followed You may not download export or re export this information except in full compliance with all applicable laws and regula...

Страница 39: ......

Страница 40: ...IBM...

Отзывы: