SAS3FLASH command
Learn about the SAS3FLASH command for the adapters 9300-8i & 9305-16i (feature codes EK41 and
EK43).
For details on using the SAS3FLASH command, see https://www.broadcom.com/products/storage/host-
bus-adapters/sas-9305-16i#downloads (www.broadcom.com/products/storage/host-bus-adapters/
sas-9305-16i#downloads). Look under the "Management Software and Tools" section, for the
SAS3FLASH_P15 archive.
See How to use Petitboot bootloader (www.ibm.com/support/knowledgecenter/linuxonibm/liabw/
liabppetitboot.html).
Sensor status
You can check the sensor status to quickly determine the general health of the system without using the
event codes.
To view the sensor status, use the following command:
openbmctool -U <username> -P <password> -H <BMC IP address or BMC host name> fru status
To view the sensor status and any corresponding event codes, use the following command:
openbmctool -U <username> -P <password> -H <BMC IP address or BMC host name> fru status -v
Sensors that have a status of present and functional do not require a service action. Sensors that have a
status of present and not functional require a service action.
Some occurrences of errors in the system might not appear in the sensor status. After you view the sensor
status, look for event codes to determine whether a service action is required.
Removing and replacing covers for the 9183-22X system
Find information about removing and replacing covers for the IBM Power System IC922 (9183-22X)
system.
Removing the service access cover from a 9183-22X system
To remove the service access cover, complete the steps in this procedure.
Procedure
1. Ensure that you removed both power supplies from the system.
For instructions, see “Preparing the 9183-22X system to remove and replace internal parts” on page
146.
(L005)
CAUTION: Hazardous energy present. Voltages with hazardous energy might cause heating
when shorted with metal, which might result in splattered metal, burns, or both. (L005)
2. At the rear of the system, loosen the cover screw (B) that fastens the cover to the chassis.
156 Power Systems: Servicing the IBM Power System IC922 (9183-22X)
Содержание Power System IC922
Страница 1: ...Power Systems Servicing the IBM Power System IC922 9183 22X IBM...
Страница 14: ...xiv Power Systems Servicing the IBM Power System IC922 9183 22X...
Страница 178: ...164 Power Systems Servicing the IBM Power System IC922 9183 22X...
Страница 189: ......
Страница 190: ...IBM...