![IBM Power System 8335-GCA Скачать руководство пользователя страница 122](http://html.mh-extra.com/html/ibm/power-system-8335-gca/power-system-8335-gca_manual_607961122.webp)
EPUB_PRC_TOD_CLOCK_ERR isolation procedure
A diagnostic function detected a problem with the time of day or clock function.
Use the following table to determine the service action:
Table 29. EPUB_PRC_TOD_CLOCK_ERR service actions
System
Service action
8335-GCA or 8335-GTA
Replace the system backplane. If replacing the system
backplane does not resolve the problem, replace system
processor CPU 1. If replacing system processor CPU 1
does not resolve the problem, replace system processor
CPU 2. Go to “8335-GCA and 8335-GTA locations” on
page 111 to identify the physical location and removal
and replacement procedure.
If replacing the system backplane and both system
processors does not resolve the problem, go to
“Contacting IBM service and support” on page 110. This
ends the procedure.
8335-GTB
Replace the system backplane. If replacing the system
backplane does not resolve the problem, replace system
processor CPU 1. If replacing system processor CPU 1
does not resolve the problem, replace system processor
CPU 2. Go to “8335-GTB locations” on page 121 to
identify the physical location and removal and
replacement procedure.
If replacing the system backplane and both system
processors does not resolve the problem, go to
“Contacting IBM service and support” on page 110. This
ends the procedure.
8348-21C
Replace the system backplane. If replacing the system
backplane does not resolve the problem, replace the
system processor. Go to “8348-21C locations” on page
133 to identify the physical location and removal and
replacement procedure.
If replacing the system backplane and the system
processor does not resolve the problem, go to
“Contacting IBM service and support” on page 110. This
ends the procedure.
EPUB_PRC_COOLING_SYSTEM_ERR isolation procedure
One or more processor sensors detected an over temperature condition.
To resolve the over temperature condition, complete the following steps:
1.
Is your system a water-cooled 8335-GTB?
If
Then
Yes:
Go to “Resolving an over temperature problem for a water-cooled 8335-GTB system” on
page 26. This ends the procedure.
No:
Continue with the next step.
2.
If your system is an 8335-GCA, 8335-GTA, or 8335-GTB, is the room temperature less than 40°C
(104°F)? If your system is an 8348-21C, is the room temperature less than 35°C (95°F)?
106
Problem analysis, system parts, and locations for the 8335-GCA, 8335-GTA, 8335-GTB, and 8348-21C
Содержание Power System 8335-GCA
Страница 2: ......
Страница 16: ...xiv Problem analysis system parts and locations for the 8335 GCA 8335 GTA 8335 GTB and 8348 21C ...
Страница 133: ...System parts Figure 6 System parts Finding parts and locations 117 ...
Страница 160: ...144 Problem analysis system parts and locations for the 8335 GCA 8335 GTA 8335 GTB and 8348 21C ...
Страница 172: ...156 Problem analysis system parts and locations for the 8335 GCA 8335 GTA 8335 GTB and 8348 21C ...
Страница 173: ......
Страница 174: ...IBM ...