6.
To confirm that you want to rebuild the data on the drive, press Enter.
The message that the rebuild has begun is shown at the bottom of the Work with Disk Unit Recovery
display. The rebuild process might take several minutes to complete.
Preparing to remove a disk drive or solid-state drive from a system or
logical partition controlled by IBM i
Learn the actions you must take to properly remove a disk drive or solid-state drive.
Before removing a drive from a system or expansion unit that is controlled by IBM i, follow these steps:
1.
Determine the protection status of the drive that you are replacing. For instructions, see “Determining
the IBM i disk drive or solid-state drive protection status” on page 114.
2.
For mirrored disk drives
on an IBM i system or logical partition, follow these steps to verify that the
drive you are replacing has been suspended:
a.
Sign on with service level authority.
b.
Type
strsst
on the command line of the IBM i session and press Enter.
c.
Type your service tools user ID and service tools password on the Start Service Tools (STRSST)
Sign On display. Press Enter.
Remember:
The service tools password is case-sensitive.
d.
Select
Work with disk units
from the System Service Tools (SST) display. Press Enter.
e.
Select
Display Disk Configuration
from the Work with Disk Units display. Press Enter.
f.
Select
Display Disk Configuration Status
from the Display Disk Configuration display. Press
Enter.
g.
Does the drive that is mirrored to the drive that you are replacing (same drive number) have a
status of Active?
v
No
: The replacement must be done by a service provider.
Confirm Rebuild Disk Unit Data
Rebuilding the disk unit data might take several minutes for each disk
selected.
Press Enter to confirm having the data rebuilt.
q=Cancel to return and change your choice.
OPT Name
PCI/SCSI Location
Description
Status
--- ------ -------------------------- ------------------------- ---------------
1
0000:58:01.0.0/0:4:0
RAID
Array Member
Failed
q=Cancel
t=Toggle
Figure 86. Example Confirm Rebuild Disk Unit Data display
Disk drives or solid-state drives