30
IBM Power 595 Technical Overview and Introduction
Additional requirements are as follows:
The 12X I/O drawer (#5797) can be used for additional I/O capacity in the 595 system rack
and both of the 595 Expansion Racks (#6953 and #6954). The 12X I/O drawer (#5798)
can only be used in the system rack.
The 9119-590/595 PCI Expansion Drawers (#5791 and #5794) can be used with the 595
system rack and Expansion Racks (#6953 and #6954).
Although not available for new orders, the 9119-595 powered Expansion Rack (#5792)
can also be used for additional 24-inch I/O drawer expansion. The powered Expansion
Rack (#5792) only supports the RIO-2 I/O Drawers (#5791 and #5794). It does not
support the 12X I/O Drawers (#5797 nor #5798). When the 9119-595 powered Expansion
Rack (#5792) is used, the nonpowered Expansion Rack (#8691) can be used for
additional I/O expansion. The feature 8691 rack is bolted onto the powered Expansion
Rack (#5792).
The 9119-595 Expansion Racks (#5792) do not support additional I/O expansion using
the 12X PCI Drawers (#5797 and #5798).
The 9119-595 Expansion Racks (#5792 and #8691) only support the RIO-2 I/O Drawers
(#5791 and #5794).
All 24-inch, 595 racks and expansion feature racks must have door assemblies installed.
Door kits containing front and rear doors are available in either slimline, acoustic, rear heat
exchanger, or acoustic rear heat exchanger styles.
Additional disk expansion for IBM i partitions is available in a 42U high, 19-inch Expansion
Rack (#0553). Both the feature #5786 SCSI (4U) and feature #5886 SAS drawers can be
mounted in this rack. Also available is the PCI-X Expansion Drawer (#5790). A maximum of
four I/O bus adapters (#1814) are available in each CEC processor book for the PCI-X
Expansion Drawer (#5790). The Expansion Drawer (#5790) must include a #6438, dual-port
RIO-G adapter which is placed into a PCI slot.
1.4.1 Door kit
The slimline door kit provides a smaller footprint alternative to the acoustical doors for those
clients who might be more concerned with floor space than noise levels. The doors are
slimmer because they do not contain acoustical treatment to attenuate the noise.
The acoustical door kit provides specially designed front and rear acoustical doors that
greatly reduce the noise emissions from the system and thereby lower the noise levels in the
data center. The doors include acoustically absorptive foam and unique air inlet and exhaust
ducts to attenuate the noise. This is the default door option.
The non-acoustical front door and rear door heat exchanger kit provides additional cooling to
reduce environmental cooling requirements for the 595 server installation. This feature
provides a smaller footprint alternative to the acoustical doors along with a Rear Door Heat
Exchanger for those clients who might be more concerned with floor space than noise levels
and also want to reduce the environmental cooling requirements for the 595 server.
Note:
One nonpowered Expansion Rack can be attached to each Powered Expansion
rack. The nonpowered Expansion Rack (#6953) cannot be attached to the 595 system
rack.
Note:
The height of the system rack or Expansion Rack features (42U) might require
special handling when shipping by air or when moving under a low doorway.