Chapter 3. Installing the Device Driver on the RS/6000 SP System

For an RS/6000 SP system, the installation tasks must be performed on each node.
You must make the installation files available and then install them on all the relevant
nodes. This chapter discusses the following tasks to enable you to install the device
driver on the RS/6000 SP system:

v

Checking System Prerequisites

v

Installing Software on the Control Workstation (

if

the device driver is not in the

lppsource directory)

v

Installing Device Drivers on the SP Nodes (

if

the device driver and additional

software are not already installed)

Perform the following tasks on the Control Workstation. If you are unfamiliar with the

dsh

command, refer to one of the following Parallel System Support Program (PSSP)

publications:

v

Parallel System Support Program for AIX: Administration Guide

v

Parallel System Support Program for AIX: Command and Technical Reference

If you cannot use the

dsh

command because of the setup at your site, then use the

telnet

command to each node. Then perform the steps below, beginning with step 5,

and omitting the

dsh

prefix.

Checking System Prerequisites

Do the following to check system prerequisites:

__ 1. Log in to the Control Workstation as a root user.

__ 2. Go to a temporary directory by typing the following at the system prompt:

cd /tmp

Press Enter.

__ 3. Make a

working collective

file containing a list of the relevant nodes on which

you want to perform the update. Type the following, pressing Enter after each
line:

cat > group1

nodename1

nodename2

nodename3......

CTRL-D

export WCOLL=/tmp/group1

__ 4. Test the working collective file by typing the following:

dsh date

7

Содержание PCI Cryptographic Coprocessor

Страница 1: ...PCI Cryptographic Coprocessor Installation and Using Guide SA23 1235 01...

Страница 2: ...Business Machines Corporation 2000 2002 All rights reserved Note to U S Government Users Restricted Rights Use duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp Note Befo...

Страница 3: ...on the SP Nodes 11 Chapter 4 Installing the PCI Cryptographic Coprocessor 13 Installing the Coprocessor 13 Verifying Coprocessor Hardware Installation 14 Verifying AIX Software Installation 15 Runnin...

Страница 4: ...iv PCI Cryptographic Coprocessor Installation and Using Guide...

Страница 5: ...xisting system before you add a device Use one hand when possible to connect or disconnect signal cables to prevent a possible shock from touching two surfaces with different electrical potentials Dur...

Страница 6: ...handle and possibly damage the device v While the device is still in its anti static package touch it to an unpainted metal part of the system unit for at least two seconds This drains static electric...

Страница 7: ...ications contain related information v System unit documentation for information specific to your hardware configuration v Operating system documentation for information specific to your software conf...

Страница 8: ...viii PCI Cryptographic Coprocessor Installation and Using Guide...

Страница 9: ...rocessor s battery powered protected memory The information from this key signs status messages to confirm that the coprocessor is genuine and that no tampering has occurred Note If any of the secure...

Страница 10: ...renders the coprocessor inoperable v Any short on the battery power distribution circuits causes a voltage drop and a Tamper Event While handling the coprocessor observe the following precautions v Do...

Страница 11: ...required See Chapter 2 Installing the Device Driver Software on page 5 or Chapter 3 Installing the Device Driver on the RS 6000 SP System on page 7 for device driver installation instructions For addi...

Страница 12: ...4 PCI Cryptographic Coprocessor Installation and Using Guide...

Страница 13: ...rocessor before you install the AIX operating system See Chapter 4 Installing the PCI Cryptographic Coprocessor on page 13 If the AIX operating system is installed on your system install the PCI Crypt...

Страница 14: ...ware 12 Press Enter 13 The INSTALL ADDITIONAL DEVICE SOFTWARE screen displays The entry fields are automatically updated Press Enter to accept the information 14 The ARE YOU SURE window displays Press...

Страница 15: ...lowing Parallel System Support Program PSSP publications v Parallel System Support Program for AIX Administration Guide v Parallel System Support Program for AIX Command and Technical Reference If you...

Страница 16: ...operating system prompt dsh oslevel OR dsh w host1 host2 oslevel Press Enter host1 host2 is a list of the host names for the nodes on which the adapter will be installed The required AIX level is 4 3...

Страница 17: ...ve the cursor down until the SPOT resource is highlighted The SPOT resource should look similar to spot_AIX421 resources spot The format of the spot name is spot_ lppsource_name lppsource_name was the...

Страница 18: ...M for the operating system as follows v AIX 4 3 x Additional Device Software __ 3 Insert the installation media into the drive of the Control Workstation __ 4 Transfer the files to the Control Worksta...

Страница 19: ...display the list of install images and select the appropriate lppsource f Move the cursor until the appropriate lppsource is displayed For example lppsource_AIX421 resources lpp_source Press Enter g M...

Страница 20: ...lled on the nodes by typing the following at the system prompt dsh installp p acqXd mnt device driver 2 1 more device driver is the fileset that must be installed for the adapter The list includes v d...

Страница 21: ...entation and install your coprocessor hardware then install the AIX operating system b If the coprocessor device driver is installed on your system go to step 3 Otherwise go to Chapter 2 Installing th...

Страница 22: ...our system go to step 9 v If the coprocessor is not hot pluggable on your system go to step 10 9 If the coprocessor is hot pluggable on your system do the following a If you use the pkcsslotd daemon s...

Страница 23: ...vel 2 2 0 0 or higher If this information displays but you continue to experience problems go to Installing the Coprocessor on page 13 v If no data displays the coprocessor device driver did not insta...

Страница 24: ...16 PCI Cryptographic Coprocessor Installation and Using Guide...

Страница 25: ...ry tray needed to provide backup power while you replace the batteries You need two battery kits to replace all four of the batteries To order the kits contact your sales representative Each Replaceme...

Страница 26: ...ries provide power to the coprocessor while you perform this step 9 Remove the battery tray from the J3 connector and discard it 10 Reinstall the coprocessor into the PCI bus slot be sure the card is...

Страница 27: ...one or more of the following measures v Reorient or relocate the receiving antenna v Increase the separation between the equipment and receiver v Connect the equipment into an outlet on a circuit diff...

Страница 28: ...ications Safety Requirements This equipment is manufactured to the International Safety Standard EN60950 and as such is approved in the UK under the General Approval Number NS G 1234 J 100003 for indi...

Страница 29: ...ct is aimed to be used in a domestic environment When used near a radio or TV receiver it may become the cause of radio interference Read the instructions for correct handling Radio Protection for Ger...

Страница 30: ...22 PCI Cryptographic Coprocessor Installation and Using Guide...

Страница 31: ...untry where such provisions are inconsistent with local law THIS MANUAL IS PROVIDED AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES O...

Страница 32: ...24 PCI Cryptographic Coprocessor Installation and Using Guide...

Страница 33: ......

Страница 34: ...Part Number 00P4106 Printed in U S A October 2002 SA23 1235 01 1P P N 00P4106...

Отзывы: