General Information about the Rebuild Operation
A physical hard disk drive can enter the rebuild state if:
You physically replace a defunct drive that is part of the critical
logical drive.
When you physically replace a defunct drive in a critical logical
drive, the ServeRAID adapter or controller rebuilds the data on
the new physical drive
before it changes the logical drive state
back to Okay.
The ServeRAID adapter or controller adds a hot-spare or a
standby hot-spare drive to the array and changes its state from
Hot-Spare or Standby Hot-Spare to Rebuilding.
Automatically Rebuilding the Defunct Drive
The ServeRAID adapter or controller will rebuild a defunct drive
automatically when all of the following conditions exist:
The physical drive that failed is part of a RAID level-1 or RAID
level-5 logical drive.
A hot-spare or standby hot-spare drive with a capacity equal to
or greater than the capacity of the defunct drive is available the
moment the drive fails.
– When multiple hot-spare drives are available, the ServeRAID
adapter or controller searches for a hot-spare drive of the
appropriate size. The smallest drive that meets this
requirement enters the Rebuild state.
– If no hot-spare or standby hot-spare drives are available, the
rebuild operation will start the moment you replace the
defective drive.
Note: If you physically replace the drive and the new drive
does not appear in the Physical Drives branch of the
Main Tree, you must scan for new or removed Ready
drives.
No rebuild, synchronization, or logical-drive migration operation is
in process.
160
IBM ServeRAID-3H and ServeRAID-3L Adapters
Содержание Netfinity ServeRAID-3H
Страница 1: ...IBM Netfinity ServeRAID 3H and ServeRAID 3L Ultra2 SCSI Adapters Installation and User s Guide ...
Страница 2: ......
Страница 3: ...IBM Netfinity ServeRAID 3H and ServeRAID 3L Ultra2 SCSI Adapters Installation and User s Guide IBM ...
Страница 8: ...vi IBM ServeRAID 3H and ServeRAID 3L Adapters ...
Страница 66: ...56 IBM ServeRAID 3H and ServeRAID 3L Adapters ...
Страница 197: ...Taiwanese Electromagnetic Interference EMI Statement Appendix A Product Warranties and Notices 187 ...
Страница 198: ...188 IBM ServeRAID 3H and ServeRAID 3L Adapters ...
Страница 211: ......
Страница 212: ...IBM Part Number 05L2054 Printed in U S A ð5L2ð54 ...