Rebuilding a Defunct Drive
When a hard disk drive goes defunct (DDD), a Rebuild operation is
required to reconstruct the data for the device in its respective disk
array. The ServeRAID adapters and controllers can reconstruct
RAID level-1 and RAID level-5 logical drives, but they cannot
reconstruct data stored in RAID level-0 logical drives.
To prevent data integrity problems, the ServeRAID adapters and
controllers set the RAID level-0 logical drives to
Blocked during a
Rebuild operation. After the Rebuild operation completes, you can
unblock the RAID level-0 logical drives, and access them once again.
But remember, the logical drive might contain damaged data. (Refer
to “Unblocking Logical Drives” on page 111 for more information.)
Before you rebuild a drive, review the following guidelines and
general information.
Guidelines for the Rebuild Operation
The replacement hard disk drive must have a capacity equal to
or greater than the failed drive.
If the hard disk drive being rebuilt is part of a RAID level-0 logical
drive, the RAID level-0 drive is blocked.
– You must unblock any RAID level-0 logical drives at the end
of the rebuild operation.
– If you use the Administration and Monitoring program to
initiate the rebuild operation, you can unblock the blocked
RAID level-0 drive when the rebuild operation completes.
(See “Unblocking Logical Drives” on page 111 for more
information.)
Data in a logical drive with RAID level-0 is lost during the rebuild
operation. If you backed up your data before the drive failed,
you can restore the data to the new drive.
Chapter 6. Solving ServeRAID Problems
159
Содержание Netfinity ServeRAID-3H
Страница 1: ...IBM Netfinity ServeRAID 3H and ServeRAID 3L Ultra2 SCSI Adapters Installation and User s Guide ...
Страница 2: ......
Страница 3: ...IBM Netfinity ServeRAID 3H and ServeRAID 3L Ultra2 SCSI Adapters Installation and User s Guide IBM ...
Страница 8: ...vi IBM ServeRAID 3H and ServeRAID 3L Adapters ...
Страница 66: ...56 IBM ServeRAID 3H and ServeRAID 3L Adapters ...
Страница 197: ...Taiwanese Electromagnetic Interference EMI Statement Appendix A Product Warranties and Notices 187 ...
Страница 198: ...188 IBM ServeRAID 3H and ServeRAID 3L Adapters ...
Страница 211: ......
Страница 212: ...IBM Part Number 05L2054 Printed in U S A ð5L2ð54 ...