new ch is the channel where the drive is now located.
new SID is the SCSI ID where the drive is now located.
For example, when drivers are imported from a server with the System
Name of
My Machine:
(My Machine:
1:6
>
1:1ð)
In this example, the message indicates that the drive from Channel 1, SCSI
ID 6 is now located at Channel 1, SCSI ID 10. The drive might have been
physically moved to a new drive bay.
Action: Press one of the following keys:
F4
Retry. Press this key after correcting the problem. For example,
press F4 after you move the hard disk drive to its previously
assigned location, or after you install the original hard disk drives
back in the server.
F5
Accept. Press this key to accept the new state that the
ServeRAID adapter or controller will assign to the drive. For
example, the ServeRAID adapter or controller will assign the
drive a state of defunct (DDD) or empty (EMP).
Note: A hard disk drive in the defunct state does not necessarily
mean that you need to replace the drive. Before you replace the
drive, ensure that:
1. All cables are connected properly to the backplane or system
board, and to the hard disk drive. Also, ensure that all cables
inside the server are connected properly.
2. The hot-swap drive trays are seated properly in the drive bay.
3. If you have not already attempted to rebuild the drive, try
rebuilding it. See “Rebuilding a Defunct Drive” on page 159
for more information.
After you perform these steps, if the hard disk drive does not
function properly, replace the drive.
F6
Modify. This choice is not always active. Press this key to
modify the configuration to match the current drive location.
You might remove the hot-swap drives from the server for
security or maintenance reasons. If you replace the drives but
install them in different drive bays, you can press F6 to accept
the new locations, and the ServeRAID adapter or controller will
update the configuration.
F7
Import. Press this key to import the configuration information
from the drive and to update the configuration information for the
ServeRAID adapter or controller. This choice is useful when you
148
IBM ServeRAID-3H and ServeRAID-3L Adapters
Содержание Netfinity ServeRAID-3H
Страница 1: ...IBM Netfinity ServeRAID 3H and ServeRAID 3L Ultra2 SCSI Adapters Installation and User s Guide ...
Страница 2: ......
Страница 3: ...IBM Netfinity ServeRAID 3H and ServeRAID 3L Ultra2 SCSI Adapters Installation and User s Guide IBM ...
Страница 8: ...vi IBM ServeRAID 3H and ServeRAID 3L Adapters ...
Страница 66: ...56 IBM ServeRAID 3H and ServeRAID 3L Adapters ...
Страница 197: ...Taiwanese Electromagnetic Interference EMI Statement Appendix A Product Warranties and Notices 187 ...
Страница 198: ...188 IBM ServeRAID 3H and ServeRAID 3L Adapters ...
Страница 211: ......
Страница 212: ...IBM Part Number 05L2054 Printed in U S A ð5L2ð54 ...