Table 19. Alarm conditions (continued)
Status
Severity
Alarm
PSU fan fail
Fault - loss of redundancy
S1
1
CFF module detected PSU fault
Fault
S1
1
PSU removed
Configuration error
None
2
Enclosure configuration error
(VPD)
Fault - critical
S1
1
Low warning temperature alert
Warning
S1
1
High warning temperature alert
Warning
S1
1
Over temperature alarm
Fault - critical
S4
3
I
2
C bus failure
Fault - loss of redundancy
S1
1
Front panel communication error
(I
2
C)
Critical fault
S1
1
IOM module fault
Fault - critical
S1
1, 4
IOM module removed
Warning
None
2
Drive power control fault
Fault - critical - loss of disk power S1
1
Insufficient power available
Warning
None
2
1
The enclosure will continue operating, requiring an administrator to take appropriate action; such as
replacing a PSU or reducing the room temperature. Alarm messages will be in the COS System
manager interface.
2
An alarm is not issued for this status and severity condition.
3
The enclosure will take action; such as shutting down in order to protect the enclosure’s data
content. Alarm messages are signaled by the SES pages (see “Enclosure management” on page 23).
4
An IOM fault will prevent data from being stored within the Disk Enclosure.
PSU and system fan faults
Overview
Table 20. PSU and system fan faults
Symptom
Cause
Recommended action
Front panel Module Fault LED is
amber
1
Any power fault
Verify AC mains connections to
the PSU are live
Amber LED is illuminated on fan
module
2
Fan failure
Replace system fan module
1
See Figure 14 on page 15 for visual reference of front panel LEDs.
2
See Figure 15 on page 17 for visual reference of PSU LEDs. See Figure 16 on page 18 visual reference
of system fan module LEDs.
Thermal monitoring and control
The storage enclosure system uses extensive thermal monitoring and takes a number of actions to ensure
component temperatures are kept low, and to also minimize acoustic noise. Air flow is from the front to
back of the enclosure.
50 IBM Cloud Object Storage System: Medium/Large J11/J12 Disk Enclosure Hardware Installation and
Maintenance Manual
Содержание Medium J11
Страница 15: ...European Community and Morocco Notice Germany Notice Safety and environmental notices xv...
Страница 102: ...82 IBM Cloud Object Storage System Medium Large J11 J12 Disk Enclosure Hardware Installation and Maintenance Manual...
Страница 103: ......
Страница 104: ...IBM...