Страница 1: ...IBM Cloud Object Storage System Version 3 14 9 Manager 3105 Appliance Manual 3401 M01 3403 M01 3409 M01 IBM ...

Страница 2: ... The information in the IBM Environmental Notices and User Guide provided on a DVD This edition applies to IBM Cloud Object Storage System Manager 3105 and is valid until replaced by new editions Copyright International Business Machines Corporation 2016 2020 US Government Users Restricted Rights Use duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp ...

Страница 3: ...fications 5 Requirements 5 Chapter 4 Install the appliance into a rack 7 Prepare for installation 7 Appliance installation 9 Chapter 5 Appliance physical interface 15 Front control panel 15 Rear panel 16 Network interface ports 17 Chapter 6 Field replaceable units 19 Replacement parts 19 Replacing external front components 19 Replace external rear components 20 Battery removal and installation 20 ...

Страница 4: ...iv ...

Страница 5: ...isk drives prior to attempting this installation Only personnel proficient in working with computer hardware and disk drives should attempt to install this appliance After all appliances have been installed in the rack refer to the Appliance Configuration Guide to configure the appliance settings required prior to setting up the system After these appliances are configured refer to the System Mana...

Страница 6: ...vi IBM Cloud Object Storage System Manager 3105 Appliance Manual ...

Страница 7: ...d a danger notice Numbers in parentheses refer to message numbers in the IBM Safety Notices publication G229 9054 which is included with your product CAUTION A caution notice indicates the presence of a hazard that has the potential of causing moderate or minor personal injury C001 DANGER A danger notice indicates the presence of a hazard that has the potential of causing death or serious personal...

Страница 8: ...viii IBM Cloud Object Storage System Manager 3105 Appliance Manual ...

Страница 9: ...Safety and environmental notices ix ...

Страница 10: ...nce with ISO 9296 1 2 3 Table 1 Declared noise emissions in accordance with ISO 9296 1 2 3 Product description Declared A Weighted Sound Power Level LWAd B Declared A Weighted Sound Pressure Level LpAm dB Operating Idling Operating Idling Models A00 A01 A02 M01 25 deg C room ambient 7 2 4 6 8 56 52 Models A00 A01 A02 M01 35 deg C room ambient 7 2 4 7 2 4 56 56 Models A00 A01 A02 M01 25 deg C room ...

Страница 11: ...workplace and may apply to you and your server installation This IBM system is available with an optional acoustical door feature that can help reduce the noise emitted from this system The actual sound pressure levels in your installation depend upon a variety of factors including the number of racks in the installation the size materials and configuration of the room where you designate the rack...

Страница 12: ...xii IBM Cloud Object Storage System Manager 3105 Appliance Manual ...

Страница 13: ...tion Technical support contacts For more information on the product or help with troubleshooting contact IBM Support at ibm com mysupport or visit the Directory of worldwide contacts Copyright IBM Corp 2016 2020 xiii ...

Страница 14: ...xiv IBM Cloud Object Storage System Manager 3105 Appliance Manual ...

Страница 15: ...Chapter 1 Manager 3105 Appliance Manual This information contains the instructions for installing and maintaining the Manager 3105 appliance Copyright IBM Corp 2016 2020 1 ...

Страница 16: ...2 IBM Cloud Object Storage System Manager 3105 Appliance Manual ...

Страница 17: ...ing Electrical Basic electrical safety precautions must be followed to protect yourself and the appliance Do not work alone with high voltage components Be aware of the locations of the power switch on the appliance and the room s emergency power off switch disconnection switch or electrical outlet If an electrical accident occurs quickly remove power from the system DANGER A danger of explosion e...

Страница 18: ...iner Remove any jewelry or metal objects from your body They are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present 4 IBM Cloud Object Storage System Manager 3105 Appliance Manual ...

Страница 19: ...he card slot highlighted Requirements Cabling Table 2 Cabling requirements for the appliance Cable Type and Usage Power Cords Use only the power cords that are supplied with the appliance Do not use another type of cord Do not use extension cords If more power cords are needed contact IBM Support 1000BASE T Copper Cables Use high quality Category 5e or 5 CAT5e CAT5 copper cables Optical Fiber Cabl...

Страница 20: ...6 IBM Cloud Object Storage System Manager 3105 Appliance Manual ...

Страница 21: ...ting temperature of the rack environment might be greater than the ambient temperature of the room Install the equipment in an environment compatible with the maximum rated ambient temperature TMRA for the appliance Sufficient airflow Mount the equipment into a rack so that the amount of airflow that is needed for safe operation is not compromised Leave enough clearance in front of the rack to ope...

Страница 22: ...iest appliances usually the Slicestor appliances on the bottom of the rack first and then work upward Unpack and inspect the box and its contents 1 Inspect outside of box for damage 2 Note if the box was damaged in any way 3 Open the top of the box and inspect for damage 4 Remove all of the components from the packaging and inspect for damage 5 Arrange for assistance lifting or installing the appl...

Страница 23: ...of the rack rails The box contains two rail kits Each rail kit contains three sections as shown in the following figure The outer rail mounts to the front rack vertical post and rear rack vertical post The middle rail allows the outer rail to extend or shorten to accommodate racks of different depths The inner rail mounts on the side of the appliance and slides into the outer rail that is mounted ...

Страница 24: ...appliance making sure that the rail faces outward in the proper orientation so that it slides into the right outer rail 2 Make sure that the inner rail screw holes and tabs are properly aligned with the matching screw holes and tab locators on the appliance 3 Install the inner rail to the appliance by aligning the key holes on the rail with the studs on the side of the appliance 4 Slide the inner ...

Страница 25: ...he rail can fit snugly into the rack 4 Align the front tabs of the outer rail with the holes in the rack post as shown in the following figure Figure 6 Aligning the outer rails with holes in rack post 5 Push the outer rail into the rack post so that the tabs go through the rack post and hold the rail in place as shown in the following figure Figure 7 Push outer rail into rack post 6 Attach the bac...

Страница 26: ...s not come out of the rack when pulled out for service Install the appliance into the rack Attach the inner rails to the appliance chassis and the outer rails to the rack CAUTION When you are ready to install the appliance in the rack you might need a lifting device Alternatively use 2 4 individuals to place the appliance in position and begin inserting it into the rack rails To install the applia...

Страница 27: ...he C13 end of the power cables to the C14 inlets in the PSU as shown in the following figure Figure 11 Rear of appliance 2 The Ethernet connections are located just to the left of the center of the appliance and are next to each other Connect a standard Ethernet cable from the left Ethernet port 3 Press the power button that is on the top far right corner of the appliance front panel when the beze...

Страница 28: ...14 IBM Cloud Object Storage System Manager 3105 Appliance Manual ...

Страница 29: ...e following figure Figure 13 Front panel buttons and LEDs for the appliance Table 4 Legend for front panel buttons and LEDs Number Description 1 System health LED 2 Disk activity LED 3 Network link activity LED 4 Unit identification button LED 5 Power button LED 6 Non maskable interrupt NMI button 7 Unused 8 Individual disk activity LED green 9 Individual disk status LED blue amber 10 Disk drive 0...

Страница 30: ...r any of the front mount hard disk drives When the green light is on or flashing the hard disk is being accessed Unit identification LED UID This LED facilitates finding a system in a rack that is viewed from the front On the front panel the LED is on the button Similarly there is also a functioning UID button LED on the back panel Power LED Power supplied to PSUs should be lit to indicate that po...

Страница 31: ...of the connection as shown in the following figure See the following table for the functions that are associated with the connection speed LED Figure 15 LAN LED connection speed indicator Table 6 LAN LED connection speed colors Color Speed Off No connection or 10 Mbps Green 100 Mbps Amber 1 Gbps 10 Gbps LAN LEDs The 10 Gbps LAN ports have two LEDs One LED indicates activity when flashing while the...

Страница 32: ...for 1 1 configuration Flashing Amber Power supply warning event where the power supply continues to operate high temp high power high current or slow fan Flashing Green AC present only five standby voltage PSU off Steady Green Output on and OK Hard disk carrier Each drive carrier has two LEDs one to indicate activity green and the other to indicate status blue amber Table 8 Conditions indicated by...

Страница 33: ...he Manager 3105 Appliance the OS data drives are in a RAID 5 configuration This allows for one drive failure with no loss of data Replacing a failed drive will automatically start the RAID rebuilding process Procedure 1 Locate the drive by location label or the solid amber failure LED 2 Press the release button on the drive carrier This action extends the carrier handle as shown in the following f...

Страница 34: ...ving a PSU from the chassis 2 Pull the PSU out using the provided handle The PSU wiring is designed to detach automatically when the PSU is pulled from the chassis 3 Replace the failed PSU with another PSU 4 Push the new PSU into the power bay until you hear a click Install an SFP QSFP optical module 1 Log in to the device as localadmin 2 At the command prompt type poweroff 3 Remove the SFP QSFP m...

Страница 35: ...tery can release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Refer to the IBM Systems Environmental Notices for battery disposal guidelines Battery installation To install an Onboard battery follow these steps 1 Identify the battery s polarity The positive side must be facing up 2 Insert the battery into the battery holder Push it down...

Страница 36: ...22 IBM Cloud Object Storage System Manager 3105 Appliance Manual ...

Страница 37: ...fications Slicestor 2584 S2584 Specification Operating Temperature C F 5 to 35 degrees C 41 95 degrees F Non operating temperature C F 40 to 70 degrees C 40 158 F Operating humidity 20 80 Non operating humidity 5 90 Dimensions without front bezel W x D x H 17 625 x 36 730 x 8 660 in 44 7675 x 93 2942 x 21 9964 cm Dimensions with front bezel W x D x H 19 000 x 36 730 x 8 660 in 48 26 x 93 2942 x 21...

Страница 38: ...4 FULL 1700 0 98 1400 0 97 Table 14 General specifications Slicestor 3448 S3448 Specification Operating Temperature C F 10 to 35 degrees C 50 95 degrees F Non operating temperature C F 40 to 65 degrees C 40 158 F Operating humidity 10 80 Non operating humidity 5 90 Dimensions without front bezel W x D x H 17 563 x 33 000 x 7 000 in 44 61002 x 83 82 x 17 78 cm Dimensions with front bezel W x D x H ...

Страница 39: ... 0 94 FULL 1050 0 99 1050 0 98 Table 17 Power measurements for Slicestor 3448 w 8tb drives FC AJ10 100v 240v Power W PF Power W PF OFF 30 0 28 60 0 38 START 950 0 96 960 0 94 FULL 1100 0 99 1100 0 98 Table 18 Power measurements for Slicestor 3448 w 10tb drives FC AJ11 100v 240v Power W PF Power W PF OFF 30 0 28 60 0 38 START 760 0 96 760 0 94 FULL 970 0 98 980 0 98 Table 19 General specifications ...

Страница 40: ...iguration Table 20 Power measurements for Slicestor 2448 w 4tb drives FC AJ0Y 100v 240v Power W PF Power W PF OFF 23 0 83 27 0 25 START 700 0 97 710 0 95 FULL 850 0 99 850 0 98 Table 21 Power measurements for Slicestor 2448 w 6tb drives FC AJ0Z 100v 240v Power W PF Power W PF OFF 24 0 83 27 0 25 START 700 0 97 710 0 95 FULL 1000 0 99 1000 0 98 Table 22 Power measurements for Slicestor 2448 w 8tb d...

Страница 41: ...imensions with front bezel W x D x H 19 000 x 27 625 x 3 4375 in 48 26 x 70 1675 x 8 73125 cm Weight 51 75 lbs 23 473405 kg Rail extended 27 5 34 5 in 69 85 87 63 cm Power cord C14 C13 connector 2 m length Input power options Voltage Range 100 240 V AC FREQUENCY 50 60hz 2 hot swappable 750W PSUs in 1 1 configuration Table 25 Power measurements for Slicestor 2212A 32GB RAM w 4tb drives FC AJ0Y 100v...

Страница 42: ...v Power W PF Power W PF OFF 35 0 27 35 0 85 START 400 0 99 400 0 95 FULL 275 0 99 285 0 92 Table 30 Power measurements for Slicestor 2212A 128GB RAM w 6tb drives FC AJ0Z 100v 240v Power W PF Power W PF OFF 35 0 27 35 0 85 START 430 0 99 440 0 95 FULL 310 0 99 320 0 92 Table 31 Power measurements for Slicestor 2212A 128GB RAM w 8tb drives FC AJ10 100v 240v Power W PF Power W PF OFF 35 0 27 35 0 85 ...

Страница 43: ...ont bezel W x D x H 19 000 x 27 625 x 1 750 in 48 26 x 70 1675 x 4 445 cm Weight 29 7 lbs 13 471693 kg Rail extended 27 5 34 5 in 69 85 87 63 cm Power cord C14 C13 connector 2 m length Input power options Voltage Range 100 240 V AC FREQUENCY 50 60hz 2 hot swappable 750W PSUs in 1 1 configuration Table 34 Power measurements for Manager 3105 100v 240v Power W PF Power W PF OFF 25 0 36 25 0 94 START ...

Страница 44: ...or Accesser 3105 100v 240v Power W PF Power W PF OFF 32 0 85 32 0 26 START 200 0 99 200 0 82 FULL 200 0 99 190 0 81 Table 37 General specifications Accesser 4105 A4105 Specification Operating Temperature C F 10 to 35 degrees C 50 95 degrees F Non operating temperature C F 40 to 65 degrees C 40 158 F Operating humidity 10 80 Non operating humidity 5 90 Dimensions without front bezel W x D x H 17 25...

Страница 45: ...put power options Voltage Range 100 240 V AC FREQUENCY 50 60hz 2 hot swappable 750W PSUs in 1 1 configuration Table 38 Power measurements for Accesser 4105 100v 240v Power W PF Power W PF OFF 32 0 85 32 0 26 START 320 1 320 0 92 FULL 240 0 99 240 0 94 Technical specifications 31 ...

Страница 46: ...32 IBM Cloud Object Storage System Manager 3105 Appliance Manual ...

Страница 47: ...apan Ltd 19 21 Nihonbashi Hakozakicho Chuo ku Tokyo 103 8510 Japan INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some jurisdictions do not allow disclaimer of express or implied warranties in...

Страница 48: ...e is entirely coincidental COPYRIGHT LICENSE This information contains sample application programs in source language which illustrate programming techniques on various operating platforms You may copy modify and distribute these sample programs in any form without payment to IBM for the purposes of developing using marketing or distributing application programs conforming to the application progr...

Страница 49: ...in your country for connection by any means whatsoever to interfaces of public telecommunications networks Further certification may be required by law prior to making any such connection Contact an IBM representative or reseller for any questions Notices 35 ...

Страница 50: ...36 IBM Cloud Object Storage System Manager 3105 Appliance Manual ...