Attention:
For this test, insert only a scratch (blank) data cartridge or a cartridge
that can be overwritten. During the test, the drive overwrites the data on the
cartridge.
Note:
If you inserted an invalid tape cartridge (e.g. Gen 1, WORM media, or
non-FMR cartridge), error code
7
appears in the SCD and the amber Fault
status LED flashes. If you inserted a write-protected cartridge, or the media
has read-only compatibility (e.g., Gen2 media), error code
P
appears in the
SCD. Press the unload button. The tape drive unloads the cartridge and
exits Maintenance Mode after the cartridge is removed.
Procedure
1.
Place the drive in Maintenance Mode. For instructions, see “Entering
Maintenance Mode” on page 18.
2.
Press the unload button once per second until
1
appears in the SCD. (If you
cycle past the desired code, press the unload button once per second until the
code reappears.)
3.
Press and hold the unload button for three or more seconds, then release it to
select function
1
. Wait for the SCD to change to a flashing
C
.
4.
Insert a scratch (blank) data cartridge. The SCD changes to a flashing
1
and
the test begins.
v
If no error is detected, the diagnostic will exit Maintenance Mode,
0
temporarily appears in the SCD, and the drive returns to Operational Mode
(SCD blank, Green Ready/Activity status LED ON, and the Amber Fault
status LED is OFF).
v
If an error is detected, the Fault status LED flashes amber and the drive
posts an error code to the SCD. To determine the error, locate the code in
“Error codes and messages” on page 46. To clear the error, either turn the
power off and then on again, or reboot the drive by pressing and holding the
unload button for 10 seconds.
Running a diagnostic self-test
Before you begin
You can use this procedure to perform a complete set of diagnostic tests on your
Ultrium 4 tape drive without affecting server operation. This 4-minute test can also
be used to verify the performance of an LTO tape cartridge.
About this task
To complete the diagnostic self-test, make sure that there is not a cartridge inserted
in the drive and complete the following steps:
Procedure
1.
Enter diagnostic mode by pressing and holding the unload button for
approximately 7 seconds. Release the button when all of the drive LEDs are lit.
2.
Insert a scratch (blank) LTO Ultrium-4 data cartridge within 15 seconds or the
drive will revert back to operating mode. If an Ultrium-4 data cartridge is not
20
LTO Ultrium 4 Half High Tape Drive
Содержание LTO Ultrium 4
Страница 2: ......
Страница 3: ...IBM LTO Ultrium 4 Half High Tape Drive Installation and User s Guide ...
Страница 10: ...viii LTO Ultrium 4 Half High Tape Drive ...
Страница 14: ...xii LTO Ultrium 4 Half High Tape Drive ...
Страница 16: ...xiv LTO Ultrium 4 Half High Tape Drive ...
Страница 80: ...64 LTO Ultrium 4 Half High Tape Drive ...
Страница 82: ...66 LTO Ultrium 4 Half High Tape Drive ...
Страница 88: ...72 LTO Ultrium 4 Half High Tape Drive ...
Страница 91: ......
Страница 92: ... Part Number 60Y1485 Printed in USA 1P P N 60Y1485 ...