Table 3. Meaning of status LED and single-character display (SCD)
Indicator
Status condition
Action
Single-
character
display (red)
"Ready" LED
(green)
"Fault" LED
(amber)
"1"
Off
On
Maximum operating temperature
exceeded
1
Reduce drive temperature.
"1" Flashing
Flashing
On
Self test is in progress
Wait for test to complete.
"2"
Off
On
Input voltage failure
Check input power
connections.
"3"
Off
Flashing
2
Drive firmware failure
3
Update to latest level
firmware.
"4"
Off
Flashing
2
Drive firmware or hardware failure
3
Clean drive and/or replace
cartridge if needed. Retry
operation. If it fails again, see
SK/ASC/ASCQ in User's
Guide for action.
"5"
Off
Flashing
2
Unrecoverable drive failure
"6"
Off
On
Drive or media failure
4
"6" or "7"
5
Off
On
Cleaning cartridge loaded, clean
failed
Replace cleaning cartridge,
which may have expired.
"7"
5
Off
On
Media error
Replace cartridge. Possible
expired cleaning cartridge.
"8"
Off
Flashing
SAS interface failure
Check SAS cable & connector.
"A"
Off
On
Recoverable drive error
6
Clean drive & retry operation.
"C"
7
Off or On
On
7
Cleaning is required (clean bit is
set)
Clean drive as soon as
possible.
"C"
7
Flashing
Off
Cleaning in progress
Wait for cleaning to complete.
"F"
5
Off
On
Incorrect firmware update tape used Replace firmware update tape.
"H"
Off
Flashing
Firmware update failed
8
Retry firmware update
operation.
"J"
5
Off
On
Incorrect (incompatible) media
Insert correct media type.
"P"
5
Off
On
Media is write-protected (and write
operation was attempted)
Use media not
write-protected.
Segments
Flashing
2
Off
Off or On
Power-on self-test in progress
Wait 30-60 seconds.
Off
Both LEDs Flashing
Together
Firmware update is in progress
Wait for update to complete.
On
9
Flashing
Rapidly
2
On
Drive is in service mode
3.0 sec On
10
3.0 sec On
10
3.0 sec On
10
After power-on self-test and drive
reset
10
Off or "C"
7
Off
Off or On
7
No cartridge is loaded
Off or "C"
7
Flashing
2
Off or On
7
Cartridge is loading or unloading
Off or "C"
7
On
Off or On
7
Cartridge is loaded, no activity
Off or "C"
7
Flashing
Off or On
7
Data cartridge is loaded, activity
12
LTO Ultrium 4 Half High Tape Drive
Содержание LTO Ultrium 4
Страница 2: ......
Страница 3: ...IBM LTO Ultrium 4 Half High Tape Drive Installation and User s Guide ...
Страница 10: ...viii LTO Ultrium 4 Half High Tape Drive ...
Страница 14: ...xii LTO Ultrium 4 Half High Tape Drive ...
Страница 16: ...xiv LTO Ultrium 4 Half High Tape Drive ...
Страница 80: ...64 LTO Ultrium 4 Half High Tape Drive ...
Страница 82: ...66 LTO Ultrium 4 Half High Tape Drive ...
Страница 88: ...72 LTO Ultrium 4 Half High Tape Drive ...
Страница 91: ......
Страница 92: ... Part Number 60Y1485 Printed in USA 1P P N 60Y1485 ...