Cache or cache-line deallocation is aimed at performing dynamic reconfiguration to bypass 
potentially failing components. This capability is provided for both L2 and L3 caches. Dynamic 
run-time deconfiguration is provided if a threshold of L1 or L2 recovered errors is exceeded.

In the case of an L3 cache run-time array single-bit solid error, the spare resources are used 
to perform a line delete on the failing line. 

PCI hot-plug slot fault tracking helps prevent slot errors from causing a system machine 
check interrupt and subsequent reboot. This provides superior fault isolation, and the error 
affects only the single adapter. Run-time errors on the PCI bus caused by failing adapters will 
result in recovery action. If this is unsuccessful, the PCI device is shut down gracefully. Parity 
errors on the PCI bus itself result in bus retry, and if uncorrected, the bus and any I/O 
adapters or devices on that bus are deconfigured.

The IntelliStation POWER 285 supports PCI Extended Error Handling (EEH) if it is supported 
by the PCI-X adapter. In the past, PCI bus parity errors caused a global machine check 
interrupt, which eventually required a system reboot in order to continue. In the IntelliStation 
POWER 285 hardware, system firmware, and AIX 5L interaction have been designed to allow 
transparent recovery of intermittent PCI bus parity errors and graceful transition to the I/O 
device available state in the case of a permanent parity error in the PCI bus.

EEH-enabled adapters respond to a special data packet generated from the affected PCI slot 
hardware by calling system firmware, which examines the affected bus, allows the device 
driver to reset it, and continues without a system reboot.

Persistent deallocation functions include:

򐂰

Processor

򐂰

Memory

򐂰

Deconfigure or bypass failing I/O adapters

򐂰

L3 cache

Following a hardware error that has been flagged by the service processor, the subsequent 
reboot of the system invokes extended diagnostics. If a processor or L3 cache is marked for 
deconfiguration by persistent processor deallocation, the boot process attempts to proceed to 
completion with the faulty device deconfigured automatically. Failing I/O adapters are 
deconfigured or bypassed during the boot process.

3.1.8  Serviceability

Increasing service productivity means the system is up and running for a longer time. The 
IntelliStation POWER 285 workstation improve service productivity by providing the functions 
described in the following sections.

Error indication and LED indicators

The IBM IntelliStation POWER 285 workstations are designed for client setup of the machine 
and for the subsequent addition of most hardware features. The IntelliStation POWER 285 
also allow clients to replace service parts (Client Replaceable Unit). To accomplish this, the 
IntelliStation POWER 285 provide internal LED diagnostics that identify parts requiring 

Note: The auto-restart (reboot) option, when enabled, can reboot the system automatically 
following an unrecoverable software error, software hang, hardware failure, or 
environmentally induced failure (such as loss of power supply).

 

 

 

 

Содержание IntelliStation POWER 285

Страница 1: ...Station POWER 285 Technical Overview and Introduction Scott Vetter Carlo Costantini Gregor Linzmeier Designed for high end mechanical computer aided design Uses leading edge IBM POWER5 processor techn...

Страница 2: ......

Страница 3: ...International Technical Support Organization IBM IntelliStation POWER 285 Technical Overview and Introduction September 2006...

Страница 4: ...ghts Use duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp Second Edition September 2006 This edition applies to IBM IntelliStation POWER 285 and IBM AIX 5L Version 5 3 p...

Страница 5: ...e POWER5 processor 10 2 2 Processor and cache 11 2 3 Memory subsystem 13 2 3 1 Memory placement rules 13 2 3 2 Memory restrictions 14 2 3 3 Memory throughput 14 2 4 Internal I O subsystem 15 2 4 1 PCI...

Страница 6: ...s 37 4 1 64 bit CATIA 38 4 1 1 Checking the AIX 5L kernel mode 39 4 1 2 Changing from a 32 bit to a 64 bit kernel 39 4 2 Checking and changing the SMT setting 39 4 3 Network Installation Management 41...

Страница 7: ...in this publication at any time without notice Any references in this information to non IBM Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web...

Страница 8: ...tem p Wake on LAN The following terms are trademarks of other companies Power Management and all Java based trademarks are trademarks of Sun Microsystems Inc in the United States other countries or bo...

Страница 9: ...king at the IBM International Technical Support Organization Austin Center Scott Vetter is a Certified IT Specialist for IBM and has over 21 years of experience with IBM He currently works in the Unit...

Страница 10: ...ts Your efforts will help increase product acceptance and customer satisfaction As a bonus you ll develop a network of contacts in IBM development labs and increase your productivity and marketability...

Страница 11: ...5 is available in a 1 core or 2 core configuration using state of the art 64 bit copper based POWER5 microprocessors running at 1 9 or 2 1GHz with 36 MB of L3 cache The base 1 GB of main memory can be...

Страница 12: ...tion POWER 285 Description Range Operating temperature 5 to 35 Celsius 41 to 95 Farenheit Relative humidity 8 to 80 Operating voltage 100 to 127 or 200 to 240 V AC auto ranging Operating frequency 50...

Страница 13: ...aged in a dual core module DCM and an integrated L3 cache soldered directly to the system board The minimum IntelliStation POWER 285 configuration must include a processor a processor entitlement memo...

Страница 14: ...1 4 1 Processor features The IntelliStation POWER 285 is available in a 1 core or 2 core configurations using state of the art 64 bit copper based POWER5 microprocessors running at 1 9 GHz or 2 1 GHz...

Страница 15: ...lightweight USB V2 attached diskette drive takes its power requirements from the USB port A USB cable is provided The drive can be attached to the integrated USB ports or to a USB adapter FC 2738 A ma...

Страница 16: ...ion control for increased productivity better design comprehension and early detection of design errors By applying fingertip control to push pull and twist the ball you manipulate the image on the sc...

Страница 17: ...s 73 4 GB 10k disk drive DVD ROM GXT4500P graphics accelerator T119 Flat Panel Monitor Power supply 700 watt Media backplane 4 pack disk drive enclosure Quiet touch keyboard USB 3 button optical mouse...

Страница 18: ...Flat Panel Monitor Power supply 700 watt Media backplane 4 pack disk drive enclosure Quiet touch keyboard USB 3 button optical mouse Processor entitlement Zero priced express activations Express offe...

Страница 19: ...s PCI X slot 2 32 bit 66 MHz 3 3 volts PCI X slot 3 32 bit 66 MHz 3 3 volts PCI X slot 4 64 bit 266 MHz 3 3 volts PCI X slot 5 64 bit 133 MHz 3 3 volts Short Long Long Short Short PCI X to PCI X bridg...

Страница 20: ...red with 389 mm The POWER5 processor is 37 smaller than the POWER5 processor It consumes less power and requires less sophisticated cooling Thus you can use the POWER5 processor in servers where previ...

Страница 21: ...controller comes ready to support for DDR 2 667 MHz DIMMs in the future Enhanced redundancy in L1 cache L2 cache and L3 directory Independent control of the L2 cache and the L3 directory for redundan...

Страница 22: ...mmand uses the performance monitor cycle counter and the processor real time clock to measure the actual processor clock speed in MHz The output in Example 2 2 is from a 2 core IntelliStation POWER 28...

Страница 23: ...emory is installed in the following order The first pair is installed in J0A and J2A The second pair is installed in J0C and J2C The third pair is installed in J0B and J2B The fourth pair is installed...

Страница 24: ...rface II bus to the processor memory controller The bus allows double reads or writes per clock cycle Because the bus operates at 1066 MHz the peak processor to memory throughput for read is 8 x 2 x 1...

Страница 25: ...3 MHz 64 bit PCI X slots Two hot swap 66 MHz 32 bit PCI X slots One hot swap DDR 266 MHz 64 bit PCI X slot The PCI X slots in the IntelliStation POWER 285 system support hot plug and extended error ha...

Страница 26: ...monitors The adapter requires one short 32 bit or 64 bit PCI X slot Figure 2 6 on page 17 shows the adapter card which has the following features and specifications Hardware description 128 bit graph...

Страница 27: ...omotive and aerospace Petroleum exploration and production Scientific visualization Other technical design and visualization This adapter has the following base features shown in Figure 2 7 on page 18...

Страница 28: ...g graphics applications in these areas Mechanical Computer Aided Design MCAD and Engineering MCAE for automotive and aerospace Petroleum exploration and production Scientific visualization LifeScience...

Страница 29: ...re 2 8 The GXT6500P graphics accelerator 2 4 4 Flat panel monitors The p5 285 deskside server when combined with a graphics accelerator can be equipped with a flat panel monitor Table 2 3 on page 19 l...

Страница 30: ...in the IntelliStation POWER 285 system Table 2 4 Orderable SCSI adapters 2 4 7 iSCSI iSCSI is an open standards based approach by which SCSI information is encapsulated using the TCP IP protocol to al...

Страница 31: ...d Linux acts as a software iSCSI initiator and allows access to iSCSI target storage devices using standard Gigabit Ethernet network adapters To ensure the best performance enable the TCP Large Send T...

Страница 32: ...elliStation POWER 285 system supports one 4 pack disk drive using a backplane that is designed for hot pluggable disk drives The disk drive backplane docks directly to the system board The virtual SCS...

Страница 33: ...anager when using disk hot swap capabilities For more information see the IBM Redbook Problem Solving and Troubleshooting in AIX 5L SG24 5496 1993 Integrated Drive Electronics IDE 4 7 GB Slimline DVD...

Страница 34: ...ments 2 1 GHz POWER5 processors AIX 5L for POWER V5 3 with 5300 04 Technology Level APAR IY77273 or later AIX 5L for POWER V5 2 with 5200 08 Technology Level APAR IY77270 or later 1 9 GHz POWER5 proce...

Страница 35: ...ion processor and contains 32 bit general purpose registers The flash ROM contains a compressed image of a software load Serviceprocessor block diagram Base FSP B D S 1 wire R ackIndC onn Flash ROM 40...

Страница 36: ...26 IBM IntelliStation POWER 285 Technical Overview and Introduction...

Страница 37: ...lp lower the total cost of ownership TCO IBM reliability availability and service RAS technology allow you to improve your TCO architecture by reducing unplanned down time This chapter provides more d...

Страница 38: ...ections describe the concepts that form the basis of leadership RAS features of IBM IntelliStation POWER 285 workstation in more detail 3 1 1 Fault avoidance IBM IntelliStation POWER 285 workstations...

Страница 39: ...cation on page 31 3 1 3 Permanent monitoring The service processor SP included in the IntelliStation POWER 285 provides a way to monitor the system even when the main processor is inoperable Mutual su...

Страница 40: ...y Single bit error correction using ECC without reaching error thresholds for main L2 and L3 cache memory L3 cache line deletes extended from 2 to 10 for additional self healing ECC extended to inter...

Страница 41: ...de Processor L3 cache line delete Partial L2 cache deallocation PCI X bus and slots For dynamic processor deallocation the service processor performs a predictive failure analysis based on any recover...

Страница 42: ...in the case of a permanent parity error in the PCI bus EEH enabled adapters respond to a special data packet generated from the affected PCI slot hardware by calling system firmware which examines th...

Страница 43: ...oling fans Power subsystems PCI X adapter cards 3 2 Manageability The functions and tools provided for IBM IntelliStation POWER 285 workstations to ease management are described in the next sections 3...

Страница 44: ...s an enhanced version of Service Director with a graphical user interface GUI Key tasks you can accomplish using Service Agent for the IBM IntelliStation POWER 285 workstation IBM System p5 pSeries an...

Страница 45: ...rvice Agent only sends outbound transmissions and does not allow any inbound connection attempts Only hardware machine configuration machine status or error information is transmitted Service Agent do...

Страница 46: ...you to manage and install microcode updates on systems and associated I O adapters For more information see the IBM microcode update Web site http www14 software ibm com webapp set2 firmware gjsn IBM...

Страница 47: ...ps This chapter contains an introduction to CATIA and several administration aids related to the IBM IntelliStation POWER 285 workstation Test and modify the scripts before placing them into productio...

Страница 48: ...ing on the investments that clients have already made on IBM platforms running AIX 5L they can instantly benefit from the advanced capabilities of the latest ENOVIA DMU and CATIA V5 software to help t...

Страница 49: ...command 5 Enter the ln fs usr lib boot unix_64 unix command 6 Enter the bosboot ad dev ipldevice command 7 Enter the sync sync sync commands 8 Enter the shutdown Fr command to reboot the 64 bit kerne...

Страница 50: ...imultaneous multithreading threads per physical or virtual processor SMT Bound Indicator that the simultaneous multithreading threads are bound on the same physical or virtual processor To enable simu...

Страница 51: ...at a convenient time For example if a client is unavailable at the time of the installation you can initiate an installation when it is back online or if there is less traffic on your network at a ce...

Страница 52: ...function Check_Disks for i in lsdev C grep hdi do echo i grep hdi awk print 1 done Check single or multi processor if bootinfo z gt 0 then MULTI mp else MULTI up fi Check system information HOSTNAME h...

Страница 53: ...REEN GRAPHIC TD BGCOLOR WHITE OUTFILEH else echo TD NOWRAP GRAPHIC TD OUTFILEH fi echo TD NOWRAP DISKS TD TR OUTFILEH Create a simple ascii list echo HOSTNAME c OUTFILEL echo MODEL c OUTFILEL echo MUL...

Страница 54: ...WITH NO WARRANTIES OR GUARANTEES WHATSOEVER usr bin perl w Created by Gregor Linzmeier IBM Deutschland GmbH pSeries Technical Support Workstation and entry Server Systems and Technology Group Northea...

Страница 55: ...n every Friday at 6 00 p m Example 4 5 Crontab entry for power off and on Crontab entry for automatic power off 0 18 5 usr local script poffpon pl 4 5 Wake on LAN Introduced with the POWER5 technology...

Страница 56: ...or Linux Applications is to provide ready to run installable open software tools and facilitate recompilation of open source software without modifications on AIX 5L systems You can order the AIX Tool...

Страница 57: ...ment the uname m command delivers the correct processor ID See Table 4 1 Table 4 1 Obtaining the correct processor ID When using partitionable systems or systems with nonhexadecimal serial numbers the...

Страница 58: ...48 IBM IntelliStation POWER 285 Technical Overview and Introduction...

Страница 59: ...SU with customer installable features CIF and customer replaceable units CRU The IntelliStation POWER 285 is considered CSU Authorized service representative set up upgraded and maintained A number of...

Страница 60: ...to help perform a variety of tasks including Preparing a site to accommodate the hardware for IBM systems Installing the server console features and options and other hardware Installing and using a H...

Страница 61: ...ulder ibm com infocenter eserver v1r3s index jsp On the HMC Click Information Center and Setup Wizard Launch the Information Center On CD ROM Shipped with the hardware English SK3T 8159 Also available...

Страница 62: ...52 IBM IntelliStation POWER 285 Technical Overview and Introduction...

Страница 63: ...chnical Overview and Introduction REDP 9111 IBM Eserver p5 550 Technical Overview and Introduction REDP 9113 IBM Eserver p5 570 Technical Overview and Introduction REDP 9117 IBM System p5 505 Express...

Страница 64: ...ocenter eserver v1r3s index jsp IBM Systems Information Centers http publib boulder ibm com eserver IBM microcode downloads http www14 software ibm com webapp set2 firmware gjsn Support for IBM System...

Страница 65: ......

Страница 66: ...paper is a comprehensive guide covering the IBM IntelliStation POWER 285 workstation We introduce major hardware offerings and discuss their prominent functions Professionals wanting to acquire a bett...

Отзывы: