Chapter 6 HPSS Configuration
HPSS Installation Guide
September 2002
407
Release 4.5, Revision 2
Starting Offset
The offset in bytes from
the beginning of the disk
logical volume at which
the Mover will begin using
the volume. The space
preceding the offset will
not be used by HPSS.
Zero, or a positive integer that is a
multiple of the Media Block Size.
Zero
Advice: This value is used for disk devices only.
Media Block Size
The block size for the
device.
Any positive 32-bit integer value.
None
Advice: This value is used for disk devices only, and must be a multiple of the
underlying disk block size.
Controller ID
An indication of the
adapter/bus that is in the
data path to the device.
Any positive 32-bit integer value.
Set to Device/
Drive ID
Advice: This field is used to attempt to mount separate volumes of a set of striped
media on separate controllers, when possible, to prevent contention on the data path.
It is recommended that the drives that are on the same adapter/bus have the same
Controller ID. For drives in 3494 and 3495 robots, the Controller ID must be a valid
ID. The valid IDs can be found in the Affinity list for any cartridge in the robot. Use
the “mtlib -l <device name> -qV -V<volume name>” to obtain the Affinity list
for a cartridge.
Polling Interval
The number of seconds to
wait between polling
requests performed by the
PVL to determine if any
media is present in the
drive.
Any positive 32-bit integer value
for polling or any negative 32-bit
integer value to disable polling.
60 seconds for
tape;
-1 for disk
Advice: This field should be set to negative to disable polling for drives that do not
support removable media. The value for drives located within robotic libraries should
probably be set higher than for manually mounted drives or set to a negative value
(preferred). We recommend that this field be set to 15 seconds for operator-mounted
tape drives, 60 for tape robots, and -1 for disk drives.
Table 6-33 Device/Drive Configuration Variables (Continued)
Display Field Name
Description
Acceptable Values
Default
Value
Содержание Hub/Switch
Страница 1: ...HPSS Installation Guide High Performance Storage System Release 4 5 September 2002 Revision 2...
Страница 12: ...12 September 2002 HPSS Installation Guide Release 4 5 Revision 2...
Страница 18: ...18 September 2002 HPSS Installation Guide Release 4 5 Revision 2...
Страница 214: ...Chapter 4 HPSS Installation 214 September 2002 HPSS Installation Guide Release 4 5 Revision 2...
Страница 412: ...Chapter 6 HPSS Configuration 412 September 2002 HPSS Installation Guide Release 4 5 Revision 2...
Страница 470: ...Chapter 8 Initial Startup and Verification 470 September 2002 HPSS Installation Guide Release 4 5 Revision 2...
Страница 488: ...Appendix B References 488 September 2002 HPSS Installation Guide Release 4 5 Revision 2...
Страница 490: ...Appendix C Developer Acknowledgments 490 September 2002 HPSS Installation Guide Release 4 5 Revision 2...
Страница 496: ...Appendix D Accounting Examples 496 September 2002 HPSS Installation Guide Release 4 5 Revision 2...
Страница 524: ...Appendix E Infrastructure Configuration Example 524 September 2002 HPSS Installation Guide Release 4 5 Revision 2...
Страница 534: ...Appendix F Additional SSM Information 534 September 2002 HPSS Installation Guide Release 4 5 Revision 2...
Страница 590: ...590 September 2002 HPSS Installation Guide Release 4 5 Revision 2...