Removing
the
blade
server
from
a
BladeCenter
unit
Attention:
v
To
maintain
proper
system
cooling,
do
not
operate
the
BladeCenter
unit
without
a
blade
server,
expansion
unit,
or
blade
filler
installed
in
each
blade
bay.
v
Note
the
bay
number.
Reinstalling
a
blade
server
into
a
different
bay
than
the
one
from
which
it
was
removed
could
have
unintended
consequences.
Some
configuration
information
and
update
options
are
established
according
to
bay
number;
if
you
reinstall
the
blade
server
into
a
different
bay,
you
might
have
to
reconfigure
the
blade
server.
To
remove
the
blade
server
from
a
BladeCenter
unit,
complete
the
following
steps.
The
appearance
of
your
BladeCenter
unit
might
be
different,
see
the
documentation
for
your
BladeCenter
unit
for
additional
information.
Release handles
(open)
1.
Read
the
safety
information
that
begins
on
page
and
2.
If
the
blade
server
is
operating,
shut
down
the
operating
system;
then,
press
the
power-control
button
(behind
the
blade
server
control
panel
door)
to
turn
off
the
blade
server
(see
for
more
information).
Attention:
Wait
at
least
30
seconds,
until
the
hard
disk
drives
stop
spinning,
before
proceeding
to
the
next
step.
3.
Pull
the
two
release
handles
to
the
open
position
as
shown
in
the
illustration.
The
blade
server
moves
out
of
the
bay
approximately
0.6
cm
(0.25
inch).
4.
Pull
the
blade
server
out
of
the
bay.
5.
Place
either
a
blade
filler
or
another
blade
server
in
the
bay
within
1
minute.
Chapter
4.
Removing
and
replacing
blade
server
components
77
Содержание HS21 - BladeCenter - 8853
Страница 1: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 8: ...vi BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 16: ...xiv BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 126: ...110 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 138: ...122 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 139: ......
Страница 140: ...Part Number 24R9701 Printed in USA 1P P N 24R9701...