Memory
problems
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
CRUs
and
which
components
are
FRUs.
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Symptom
Action
The
amount
of
system
memory
that
is
displayed
is
less
than
the
amount
of
installed
physical
memory.
1.
Make
sure
that:
v
You
have
installed
the
correct
type
of
memory.
v
If
you
changed
the
memory,
you
updated
the
memory
configuration
in
the
Configuration/Setup
Utility
program.
v
All
banks
of
memory
are
enabled.
The
blade
server
might
have
automatically
disabled
a
memory
bank
when
it
detected
a
problem,
or
a
memory
bank
might
have
been
manually
disabled.
2.
Check
BMC
log
for
error
message
289:
v
If
a
DIMM
was
disabled
by
a
system-management
interrupt
(SMI),
replace
the
DIMM.
v
If
a
DIMM
was
disabled
by
the
user
or
by
POST,
run
the
Configuration/Setup
Utility
program
and
enable
the
DIMM.
3.
Reseat
the
DIMM,
and
the
Memory
and
I/O
Expansion
Blade
if
one
is
installed.
4.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
Memory
and
I/O
Expansion
Blade
(if
one
is
installed)
b.
Replace
the
DIMM.
c.
(Trained
service
technician
only)
System
board
assembly
Multiple
rows
of
DIMMs
in
a
branch
are
identified
as
failing.
1.
Reseat
the
DIMMs;
then,
restart
the
server.
2.
Replace
the
lowest-numbered
DIMM
pair
of
those
that
are
identified;
then,
restart
the
server.
Repeat
as
necessary.
3.
(Trained
service
technician
only)
Replace
the
system
board.
Microprocessor
problems
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
CRUs
and
which
components
are
FRUs.
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Symptom
Action
The
blade
server
emits
a
continuous
beep
during
POST,
indicating
that
the
startup
(boot)
microprocessor
is
not
working
correctly.
1.
(Trained
service
technician
only)
Reseat
microprocessor
1.
2.
(Trained
service
technician
only)
Replace
microprocessor
1.
42
BladeCenter
HS21
Types
1885
and
8853:
Problem
Determination
and
Service
Guide
Содержание HS21 - BladeCenter - 8853
Страница 1: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 8: ...vi BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 16: ...xiv BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 126: ...110 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 138: ...122 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 139: ......
Страница 140: ...Part Number 24R9701 Printed in USA 1P P N 24R9701...