4.
If
a
Memory
and
I/O
Expansion
Blade
is
installed
and
you
are
removing
DIMMs
from
the
system
board,
remove
the
Memory
and
I/O
Expansion
Blade
(see
5.
Locate
the
DIMM
connectors.
Determine
which
DIMM
you
want
to
remove
from
the
blade
server.
Attention:
To
avoid
breaking
the
retaining
clips
or
damaging
the
DIMM
connectors,
handle
the
clips
gently.
6.
Move
the
DIMM
retaining
clips
on
the
side
of
the
DIMM
socket
to
the
open
position
by
pressing
the
retaining
clips
away
from
the
center
of
the
DIMM
socket.
7.
Using
your
fingers,
pull
the
DIMM
out
of
the
DIMM
socket.
8.
If
you
are
instructed
to
return
the
DIMM,
follow
all
packaging
instructions,
and
use
any
packaging
materials
for
shipping
that
are
supplied
to
you.
Installing
a
memory
module
For
blade
servers
with
no
Memory
and
I/O
Expansion
Blade,
when
you
install
memory,
you
must
install
a
pair
of
matched
DIMMs.
Install
the
DIMMs
in
the
following
order:
Pair
DIMM
connectors
First
1
(J141)
and
3
(J143)
Second
2
(J142)
and
4
(J144)
To
set
up
a
non-mirrored
memory
configuration
for
a
blade
server
with
a
Memory
and
I/O
Expansion
Blade,
when
you
install
memory,
you
must
install
a
pair
of
matched
DIMMs.
Install
the
DIMMs
in
the
following
order:
Pair
DIMM
connectors
First
1
(system
board
J141)
and
3
(system
board
J143)
Second
5
(Memory
and
I/O
Expansion
Blade
J18)
and
7
(Memory
and
I/O
Expansion
Blade
J20)
Third
2
(system
board
J142)
and
4
(system
board
J144)
Fourth
6
(Memory
and
I/O
Expansion
Blade
J19)
and
8
(Memory
and
I/O
Expansion
Blade
J21)
To
set
up
a
mirrored
memory
configuration
for
a
blade
server
with
a
Memory
and
I/O
Expansion
Blade,
when
you
install
memory,
you
must
install
matched
DIMMs
in
groups
of
four.
Install
the
DIMMs
in
the
following
order:
Group
DIMM
connectors
First
1
(system
board
J141)
and
3
(system
board
J143)
5
(Memory
and
I/O
Expansion
Blade
J18)
and
7
(Memory
and
I/O
Expansion
Blade
J20)
Second
2
(system
board
J142)
and
4
(system
board
J144)
6
(Memory
and
I/O
Expansion
Blade
J19)
and
8
(Memory
and
I/O
Expansion
Blade
J21)
88
BladeCenter
HS21
Types
1885
and
8853:
Problem
Determination
and
Service
Guide
Содержание HS21 - BladeCenter - 8853
Страница 1: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 8: ...vi BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 16: ...xiv BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 126: ...110 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 138: ...122 BladeCenter HS21 Types 1885 and 8853 Problem Determination and Service Guide...
Страница 139: ......
Страница 140: ...Part Number 24R9701 Printed in USA 1P P N 24R9701...