Procedure
To install the hard disk drive cage, complete the following steps.
Screws
Hard disk
drive cage
1.
Remove the cover (see “Removing the compute node cover” on page 498).
2.
Position the cage in the bezel at an angle and rotate the cage into position on
the system board.
3.
Align the cage with the screw holes on the system board.
4.
Using a T8 Torx screwdriver, install the four screws and secure the cage in the
compute node.
5.
Install the hard disk drive backplane (see “Installing the hard disk drive
backplane” on page 521).
6.
Insert the hot-swap hard disk drives and hard disk drive bay fillers (see
“Installing a hot-swap hard disk drive” on page 523).
What to do next
After you install the hard disk drive cage, complete the following steps:
1.
Install the cover onto the compute node (see “Installing the compute node
cover” on page 500 for instructions).
2.
Install the compute node into the chassis (see “Installing a compute node in a
chassis” on page 490 for instructions).
Removing a fabric connector
Use this information to remove a fabric connector.
Before you begin
Note:
This procedure should be performed only by trained service technicians.
Before you remove the fabric connector, complete the following steps:
1.
Read “Safety” on page v and “Installation guidelines” on page 487.
2.
If the compute node is installed in an IBM Flex System chassis, remove it (see
“Removing a compute node from a chassis” on page 489 for instructions).
3.
Carefully lay the compute node on a flat, static-protective surface, orienting the
compute node with the bezel pointing toward you.
Chapter 7. Installing, removing, and replacing compute node components
537
Содержание Flex System x440 Compute Node
Страница 1: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 34: ...22 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 50: ...38 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 68: ...56 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 498: ...486 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 570: ...558 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 578: ...566 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 583: ......
Страница 584: ... Part Number 81Y1144 Printed in USA 1P P N 81Y1144 ...