Troubleshooting by symptom
Use this information to find solutions to problems that have identifiable symptoms.
To use the symptom-based troubleshooting tables in this section, complete the
following steps:
1.
Check the IMM event log and follow the suggested actions to resolve any event
codes (see “IMM event log” on page 63).
2.
Find the symptoms that you are experiencing in the troubleshooting tables in
this section and follow the suggested actions to resolve any problems.
3.
If the problem remains, submit a service request (see http://
ralfss21.raleigh.ibm.com:8099/help/topic/com.ibm.acc.common.nav.doc/
getting_help_and_technical_assistance.html).
Compute node start problems
Use this information to solve compute node start problems.
Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved.
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. See Chapter 5, “Parts listing, Types 7917 and 2584,” on page 51 to determine which components are Tier 1
customer replaceable units (CRUs) and which components are Tier 2 customer replaceable units (CRUs).
Symptom
Action
Embedded hypervisor is not in
the boot list
1.
If the compute node has recently been installed, moved, or serviced, or if this
is the first time the embedded hypervisor is being used, make sure that the
device is connected properly and that there is no physical damage to the
connectors.
2.
Go to http://www.ibm.com/systems/info/x86servers/serverproven/compat/
us/ to validate that the embedded hypervisor device is supported for the
compute node.
3.
Use the Setup utility to make sure that the embedded hypervisor device (USB
key) is in the startup sequence. From the Setup utility, select
Start Options
.
4.
Check http://www.ibm.com for any service bulletins related to the embedded
hypervisor and the compute node.
5.
Make sure that other software works on the compute node to ensure that the
compute node is working properly.
Connectivity problems
Use this information to solve connectivity problems.
The IBM Flex System Manager management node cannot
communicate with a compute node
Use the information in this section to troubleshoot the IBM Flex System
Managermanagement node when the management node cannot communicate with
a compute node.
Action
Complete the following steps until the problem is solved:
1.
Make sure that the protocols that you are using are enabled.
Chapter 6. Troubleshooting
459
Содержание Flex System x440 Compute Node
Страница 1: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 34: ...22 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 50: ...38 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 68: ...56 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 498: ...486 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 570: ...558 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 578: ...566 IBM Flex System x440 Compute Node Types 7917 and 2584 Installation and Service Guide ...
Страница 583: ......
Страница 584: ... Part Number 81Y1144 Printed in USA 1P P N 81Y1144 ...