2.
To save the location code information for each Fibre Channel adapter (fcs), enter the
lsdev
command
as follows:
lsdev -vpd | grep fcs | tee LSDEV_OUTPUT_before
The output might look like the following example:
fcs0
U78AF.001.startSN-P1-C35-L1-T1
Dual Port 8Gb FC Mezzanine Card (7710322577107501)
fcs1
U78AF.001.startSN-P1-C35-L1-T2
Dual Port 8Gb FC Mezzanine Card (7710322577107501)
In this example, the original serial number is represented as
startSN
.
Restore vfchost map data
After you replace physical components on your compute node, you must review the virtual Fibre
Channel vfchost mapping. If the vfchost mapping has changed after component replacement, you must
restore the mapping.
Before you begin
To restore vfchost data, you must have first saved the original vfchost data and the physical Fibre
Channel adapter (fcs) location code information. For information, see “Save vfchost map data” on page
478.
Procedure
To restore the vfchost mapping data, use the third field of the Fibre Channel adapter (fcs) location codes,
which is the serial number field, and compare the new Fibre Channel adapter (fcs) location codes to the
original location codes. Perform a vfcmap of the new Fibre Channel adapter (fcs) to the appropriate
vfchost.
To restore the vfchost mapping data, complete the following steps by using the padmin user account:
1.
To save the new Fibre Channel adapter (fcs) location codes, use the
lsdev –vpd
command as follows.
Enter the command from the command-line interface on the source Virtual I/O Server (VIOS):
lsdev -vpd | grep fcs | tee LSDEV_OUTPUT_after1
The output might look like the following example:
fcs0
U78AF.001.startSN-P1-C35-L1-T1
Dual Port 8Gb FC Mezzanine Card (7710322577107501)
fcs1
U78AF.001.startSN-P1-C35-L1-T2
Dual Port 8Gb FC Mezzanine Card (7710322577107501)
2.
To associate the new fcsx adapter to the old fcsx adapter use the adapter slot number. Enter the
grep
command as shown in the example below:
grep "P1-C35-L1-T1" LSDEV_OUTPUT_before
LSDEV_OUTPUT_after
The output might look like the following example:
LSDEV_OUTPUT_before:
fcs0 U78AF.001.startSN-P1-C35-L1-T1 Dual Port 8Gb FC Mezzanine Card (7710322577107501)
LSDEV_OUTPUT_after1:
fcs0 U78AF.001.newSN99-P1-C35-L1-T1 Dual Port 8Gb FC Mezzanine Card (7710322577107501)
In this example, the original serial number is represented as
startSN
, the new serial number is
represented as
newSN99
, and the fcsx remained fcs0; therefore, fcs0 will be mapped to the vfchost.
Chapter 8. Troubleshooting
479
Содержание Flex System p270 Compute Node
Страница 1: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Страница 2: ......
Страница 3: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Страница 38: ...26 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 40: ...28 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 110: ...98 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 498: ...486 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Страница 509: ...Appendix Notices 497 ...
Страница 510: ...IBM Printed in USA ...