3.
With one person on each side, lift the chassis into position in the rack:
■
For two-post rack mounting, align the bottom hole in each mounting bracket
with a hole in each rack rail.
■
For four-post rack or cabinet mounting, position the device so that the bottom
rear edge of the chassis rests on the support shelf you installed earlier as
shown in Figure 5 on page 7.
WARNING:
Do not attempt to lift the chassis by the handles on the power supplies
or on the common Form-factor Modules (CFMs). The handles may break off causing
the chassis to fall and inflict injury.
Figure 11: Lift the Chassis into the Rack
4.
Use the screws to attach the left and right brackets to the rack.
5.
Visually inspect the alignment of the chassis. If the chassis is installed properly
in the rack, all the mounting screws on one side of the rack should be aligned
with the mounting screws on the opposite side, and the chassis should be level.
Reinstall Components
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and
connect the strap to one of the ESD points on the chassis. For more information
about ESD, see the
IBM Ethernet Appliance J34S Hardware Guide
.
2.
Slide each component into the chassis evenly so that it does not become stuck
or damaged.
4.
Tighten the captive screws or lock any levers for each component installed.
12
■
Step 3: Install the Device
IBM Ethernet Appliance J34S Getting Started Guide