VPD
Informational
Codes
The
following
values
of
word
13
indicate
a
VPD
informational
message:
E104,
E10D,
E112,
E113,
E114.
No
action
is
required
by
the
customer
or
service
representative.
HMC
Surveillance
Error
Codes
The
HMC
surveillance
error
codes
generated
only
by
the
HMC
are
listed
in
the
following
table.
Error
Code
Description
Action/
Possible
Failing
FRU
B301
0001
HMC/partition
surveillance
fault
Contact
service
support.
B301
0002
HMC/partition
surveillance
fault
Verify
the
network
between
the
HMC
and
the
partition
by
pinging
in
both
directions.
If
problems
are
found,
correct
them.
Reboot
the
HMC.
B301
0012
HMC/partition
surveillance
fault
Contact
service
support.
B301
0013
HMC/partition
surveillance
fault
Contact
service
support.
B301
0019
HMC/partition
surveillance
fault
Contact
service
support.
B301
0020
HMC/partition
surveillance
fault
Contact
service
support.
B301
0023
HMC/partition
surveillance
fault
Contact
service
support.
B301
0025
HMC/partition
surveillance
fault
Contact
service
support.
B301
0026
HMC/partition
surveillance
fault
Contact
service
support.
B301
0027
HMC/partition
surveillance
fault
1.
If
short
host
names
are
being
used
for
the
HMC
and
the
partitions,
ensure
that
the
short
host
names
are
set
up
correctly
according
to
the
instructions
in
″
Using
Network
Adapters
to
Communicate
with
Partitions
″
in
the
IBM
Hardware
Management
Console
for
pSeries
Installation
and
Operations
Guide
.
Correct
any
problems
that
are
found,
then
verify
that
you
can
ping
in
both
directions
between
the
HMC
and
partitions.
2.
If
short
host
names
are
not
being
used,
or
the
previous
step
does
not
correct
the
problem,
contact
service
support.
B301
0029
HMC/partition
surveillance
fault
Contact
service
support.
B301
002B
HMC/partition
surveillance
fault
Contact
service
support.
B301
002C
HMC/partition
surveillance
fault
Contact
service
support.
B301
002D
HMC/partition
surveillance
fault
Contact
service
support.
B302
0001
HMC/partition
surveillance
fault
1.
If
short
host
names
are
being
used
for
the
HMC
and
the
partitions,
ensure
that
the
short
host
names
are
set
up
correctly
according
to
the
instructions
in
″
Using
Network
Adapters
to
Communicate
with
Partitions
″
in
the
IBM
Hardware
Management
Console
for
pSeries
Installation
and
Operations
Guide
.
Correct
any
problems
that
are
found,
then
verify
that
you
can
ping
in
both
directions
between
the
HMC
and
partitions.
2.
If
short
host
names
are
not
being
used,
or
the
previous
step
does
not
correct
the
problem,
contact
service
support.
Chapter
5.
Error
Code
to
FRU
Index
769
Содержание eserver pSeries 690
Страница 1: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Страница 2: ......
Страница 3: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Страница 12: ...x Eserver pSeries 690 Service Guide...
Страница 14: ...xii Eserver pSeries 690 Service Guide...
Страница 228: ...Step 1527 5 Call your next level of support 212 Eserver pSeries 690 Service Guide...
Страница 357: ...Step 1543 15 Call for support This ends the procedure Chapter 3 Maintenance Analysis Procedures 341...
Страница 362: ...Step 1545 15 Call for support This ends the procedure 346 Eserver pSeries 690 Service Guide...
Страница 365: ...Step 1546 15 Call for support This ends the procedure Chapter 3 Maintenance Analysis Procedures 349...
Страница 381: ...Step 154A 14 Turn off the power Chapter 3 Maintenance Analysis Procedures 365...
Страница 430: ...414 Eserver pSeries 690 Service Guide...
Страница 798: ...782 Eserver pSeries 690 Service Guide...
Страница 868: ...Media Subsystem Internal Cables 1021 p690 Cable Installation and Management 1022 852 Eserver pSeries 690 Service Guide...
Страница 910: ...MCM Installation Shorts Test Step 3 See L3 Cache Modules on page 898 894 Eserver pSeries 690 Service Guide...
Страница 923: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 907...
Страница 924: ...L3 Cache Shorts Test Step 5 908 Eserver pSeries 690 Service Guide...
Страница 926: ...L3 Cache Shorts Test Step 2 910 Eserver pSeries 690 Service Guide...
Страница 928: ...L3 Cache Shorts Test Step 4 912 Eserver pSeries 690 Service Guide...
Страница 929: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 913...
Страница 1055: ...7040 Model 681 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 1039...
Страница 1057: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 1041...
Страница 1061: ...Power Cabling Chapter 10 Parts Information 1045...
Страница 1090: ...1074 Eserver pSeries 690 Service Guide...
Страница 1094: ...1078 Eserver pSeries 690 Service Guide...
Страница 1109: ...error Handle unexpected modem responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix D Modem Configurations 1093...
Страница 1122: ...1106 Eserver pSeries 690 Service Guide...
Страница 1123: ...Appendix E Ground Path The ground path for the pSeries 690 is shown in the following figure 1107...
Страница 1124: ...1108 Eserver pSeries 690 Service Guide...
Страница 1132: ...1116 Eserver pSeries 690 Service Guide...
Страница 1133: ......
Страница 1134: ...Printed in U S A February 2004 SA38 0589 05...