Operator
Panel
Error
Codes
Attention:
If
you
replace
FRUs
or
perform
an
action
on
an
I/O
subsystem
and
the
problem
is
still
not
corrected,
go
to
unless
you
were
already
directed
to
any
MAP
154
x
by
the
error
code.
Otherwise
call
support
if
the
action(s)
for
an
error
code
do
not
resolve
the
problem.
Attention:
If
the
error
code
that
brought
you
to
this
chapter
originated
in
the
AIX
error
log,
remember
that
an
error
may
require
an
additional
15
minutes
to
be
propagated
to
the
AIX
error
log.
If
you
replace
FRUs
and
the
problem
is
corrected,
go
to
″
MAP
0410:
Repair
Checkout
″
in
the
RS/6000
and
Eserver
pSeries
Diagnostic
Information
for
Multiple
Bus
Systems
.
Error
Code
Description
Action/
Possible
Failing
FRU
0000
1111
At
power
on,
failure
of
power-good
signal
from
power
supply
1.
Primary
I/O
backplane
Location:
U1.18-P1-H2
2.
DCAs
providing
power
to
the
primary
I/O
book
Locations:
U1.18-P1-V1,
U1.18-P1-V2
0000
1112
At
power
off,
failure
of
power-good
signal
from
power
supply
1.
Primary
I/O
backplane
Location:
U1.18-P1-H2
2.
DCAs
providing
power
to
the
primary
I/O
book
Locations:
U1.18-P1-V1,
U1.18-P1-V2
0000
1113
While
powered
on,
failure
of
power-good
signal
from
power
supply
1.
Primary
I/O
backplane
Location:
U1.18-P1-H2
2.
DCAs
providing
power
to
the
primary
I/O
book
Locations:
U1.18-P1-V1,
U1.18-P1-V2
0000
1114
Operator
panel
and
service
processor
have
been
reset
after
main
power
disturbance
Informational
message
0000
2222
Operator
panel
not
communicating
with
service
processor
1.
If
system
cannot
be
powered
off,
reset
the
service
processor
(via
the
pinhole
reset
or
by
disconnecting
then
reconnecting
power).
2.
Primary
I/O
book,
Location:
U1.18-P1-H2
0000
3333
SPCN
communications
error
Primary
I/O
book,
Location:
U1.18-P1-H2
0000
3334
I2C
repeater
error
Primary
I/O
book,
Location:
U1.18-P1-H2
0000
BBBB
Time-of-day
battery
malfunction
Time-of-day
battery
Location:
U1.18-P1-H2-V1
Chapter
5.
Error
Code
to
FRU
Index
421
Содержание eserver pSeries 690
Страница 1: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Страница 2: ......
Страница 3: ...pSeries 690 Service Guide SA38 0589 05 ERserver...
Страница 12: ...x Eserver pSeries 690 Service Guide...
Страница 14: ...xii Eserver pSeries 690 Service Guide...
Страница 228: ...Step 1527 5 Call your next level of support 212 Eserver pSeries 690 Service Guide...
Страница 357: ...Step 1543 15 Call for support This ends the procedure Chapter 3 Maintenance Analysis Procedures 341...
Страница 362: ...Step 1545 15 Call for support This ends the procedure 346 Eserver pSeries 690 Service Guide...
Страница 365: ...Step 1546 15 Call for support This ends the procedure Chapter 3 Maintenance Analysis Procedures 349...
Страница 381: ...Step 154A 14 Turn off the power Chapter 3 Maintenance Analysis Procedures 365...
Страница 430: ...414 Eserver pSeries 690 Service Guide...
Страница 798: ...782 Eserver pSeries 690 Service Guide...
Страница 868: ...Media Subsystem Internal Cables 1021 p690 Cable Installation and Management 1022 852 Eserver pSeries 690 Service Guide...
Страница 910: ...MCM Installation Shorts Test Step 3 See L3 Cache Modules on page 898 894 Eserver pSeries 690 Service Guide...
Страница 923: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 907...
Страница 924: ...L3 Cache Shorts Test Step 5 908 Eserver pSeries 690 Service Guide...
Страница 926: ...L3 Cache Shorts Test Step 2 910 Eserver pSeries 690 Service Guide...
Страница 928: ...L3 Cache Shorts Test Step 4 912 Eserver pSeries 690 Service Guide...
Страница 929: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 913...
Страница 1055: ...7040 Model 681 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 1039...
Страница 1057: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 1041...
Страница 1061: ...Power Cabling Chapter 10 Parts Information 1045...
Страница 1090: ...1074 Eserver pSeries 690 Service Guide...
Страница 1094: ...1078 Eserver pSeries 690 Service Guide...
Страница 1109: ...error Handle unexpected modem responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix D Modem Configurations 1093...
Страница 1122: ...1106 Eserver pSeries 690 Service Guide...
Страница 1123: ...Appendix E Ground Path The ground path for the pSeries 690 is shown in the following figure 1107...
Страница 1124: ...1108 Eserver pSeries 690 Service Guide...
Страница 1132: ...1116 Eserver pSeries 690 Service Guide...
Страница 1133: ......