configuration change to persist beyond the next reboot of the switch, you must
run the
copy running-config startup-config
command. This command stores
the current switch configuration and all changes in NVRAM.
If the switch restarts and the management module cannot apply the saved
configuration, the switch defaults to the configuration that was previously saved.
If the IP subnet address of the switch does not match the IP subnet address of
the management module, you can no longer manage the switch from the
management module. For more information about configuring the switch, see the
Command Reference
for the switch.
v
When you use the management-module Web interface to update the switch
configuration, the management-module firmware saves the new configuration in
internal nonvolatile random-access memory (NVRAM). If the switch restarts, the
management module applies the saved configuration to the switch. For more
information, see the
Application
guide and
Command Reference
.
v
For switch communication with a remote management station, such as an IBM
Director management server, through the management-module external Ethernet
port, the switch internal-network interface and the management-module external
interface must be on the same IP subnet.
For specific details about configuring the switch and preparing for system
installation, see the documentation listed in “Related documentation” on page 1.
Notes:
v
Unless otherwise stated, references to the management module apply only to the
IBM Flex System Chassis Management Module, which is the only type of
management module that supports the switch.
v
Throughout this document, the management-module Web-based user interface is
also known as the IBM Flex System management-module Web interface.
v
Throughout this document, the user name is also known as the login name or
user ID for logging on to interfaces or programs.
v
The screens that are described or referenced in this document might differ
slightly from the screens that are displayed by your system. Screen content
varies according to the type of IBM Flex System chassis and the firmware
versions and options that are installed.
Establishing a TCP/IP session through the management module
To establish a TCP/IP session for the switch through the IBM Flex System Chassis
Management Module (CMM), complete the following steps:
1. Log on to the IBM Flex System Chassis Management Module (CMM) CLI as
described in the
User’s Guide
or
Command Line Interface Reference Guide
for
the CMM. If necessary, obtain the IP address of the management module from
your system administrator.
Note:
The
User ID
and
Password
fields are case-sensitive. Type your
information in uppercase letters only. To maintain system security,
change your password after you log on for the first time. The default
User ID is
USERID
, and the default password is
PASSW0RD
(where the sixth
character is the number zero, not the letter O).
2. Set the environment to the bay where you installed the switch:
system> env -T system:switch[1]
20
EN4093 and EN4093R 10 Gb Scalable Switch: User's Guide
Содержание EN4093R
Страница 1: ...IBM Flex System Fabric EN4093 and EN4093R 10 Gb Scalable Switch User s Guide...
Страница 2: ......
Страница 3: ...IBM Flex System Fabric EN4093 and EN4093R 10 Gb Scalable Switch User s Guide...
Страница 28: ...18 EN4093 and EN4093R 10 Gb Scalable Switch User s Guide...
Страница 46: ...36 EN4093 and EN4093R 10 Gb Scalable Switch User s Guide...
Страница 54: ...44 EN4093 and EN4093R 10 Gb Scalable Switch User s Guide...
Страница 58: ...48 EN4093 and EN4093R 10 Gb Scalable Switch User s Guide...
Страница 59: ......
Страница 60: ...Part Number 47C9175 Printed in USA 1P P N 47C9175...