Table 21. Symptom-to-FRU index (continued)
Problem indicator Component
Possible cause
Possible solutions
Unable to access
drives
Drives and
fibre-channel
loop
Incorrect storage
expansion enclosure
ID settings
Ensure that the fibre-channel
optical cables are undamaged
and properly connected. Check
the storage expansion enclosure
ID settings.
Note:
For information on how to
change the storage expansion
enclosure ID if required, refer to
the online Help in the DS
Storage Manager GUI.
ESM failure
Replace one or both ESMs.
Contact an IBM technical support
representative.
Drive or drives
failed
Replace failed drive or drives.
Drive is not
certified
Check the DS3950 product Web
site for the correct drive option
P/N or FRU P/N certified for
your DS3950 storage subsystem.
Random errors
Subsystem
Midplane failure
Have the midplane replaced.
Contact an IBM technical support
representative.
Hard disk drive
not visible in
RAID
management
software
Several FRUs
Drive or drives
failed
Replace failed drive or drives.
FC cable failed
Replace FC cable.
SFP failed
Replace SFP.
ESM failure
Replace ESM.
Midplane failure
Have the midplane replaced.
Contact an IBM technical support
representative.
Incorrect firmware
version
Verify that the DS3950 storage
subsystem has been upgraded to
the correct firmware version.
Refer to “Firmware updates” on
page 49.
Parts listing
Figure 41 on page 101 and the following table provide a parts listing for the
EXP395.
100
IBM System Storage DS3950 EXP395 Storage Expansion Enclosure: Installation, User’s, and Maintenance Guide
Содержание DS3950
Страница 44: ...20 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 88: ...64 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 116: ...92 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 128: ...104 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 136: ...112 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 144: ...120 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 148: ...124 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 160: ...136 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 180: ...156 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 184: ...160 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 185: ......
Страница 186: ...Part Number 46W6896 Printed in USA GA32 0956 04 1P P N 46W6896...