snap
–gbc
–
snap
–e
(This
gives
HACMP
specific
dump.)
v
The
command
output
tells
you
where
the
dumps
are
located.
AIX
HACMP
failures
The
following
command
gives
you
a
good
overview
of
the
current
status
of
the
HACMP
clusters.
This
is
run
from
the
command
line
in
AIX:
/usr/es/sbin/cluster/clstat
Alternately,
you
can
use
the
smitty
menus
to
accomplish
the
above.
Error
indication
and
LED
indicators
The
DR550
SSAM
Server
is
designed
for
client
setup
of
the
machine
and
for
the
subsequent
addition
of
most
hardware
features.
The
DR550
SSAM
Server
also
allows
clients
to
replace
service
parts
(Client
Replaceable
Unit).
To
accomplish
this,
the
DR550
SSAM
Server
provides
internal
LED
diagnostics
that
identify
the
parts
that
require
service.
Attenuation
of
the
error
is
provided
through
a
series
of
light
attention
signals,
starting
on
the
exterior
of
the
system
(System
Attention
LED)
which
is
located
on
the
front
of
the
system
and
ending
with
an
LED
near
the
failing
Field
Replaceable
Unit.
For
more
information
about
Client
Replaceable
Units,
including
videos,
see
http://publib.boulder.ibm.com/eserver.
System
attention
LED
The
attention
indicator
is
represented
externally
by
an
amber
LED
on
the
operator
panel
and
on
the
back
of
the
system
unit.
The
amber
LED
indicates
that
the
system
is
in
one
of
the
following
states:
v
Normal
state,
LED
is
off.
v
Fault
state,
LED
is
on
solid.
v
Identify
state,
LED
is
blinking.
Additional
LEDs
on
I/O
components
such
as
PCI-X
slots
and
disk
drives
provide
status
information
such
as
power,
hot-swap,
and
need
for
service.
Concurrent
maintenance
Concurrent
maintenance
provides
replacement
of
the
following
parts
while
the
system
remains
running:
v
Disk
drives
v
Cooling
fans
v
Power
subsystems
v
PCI-X
adapter
cards
v
Operator
Panel
Indicators
in
IBM
Director
For
a
description
of
the
indicators
in
IBM
Director
console,
see
the
information
about
monitoring
the
DR550
with
IBM
Director,
in
the
DR550
User's
Guide
.
14
DR550
Version
4.5
Problem
Determination
and
Service
Guide
Содержание DR550
Страница 1: ...IBM System Storage DR550 Version 4 5 Problem Determination and Service Guide GA32 0576 00...
Страница 2: ......
Страница 3: ...IBM System Storage DR550 Version 4 5 Problem Determination and Service Guide GA32 0576 00...
Страница 4: ...ii DR550 Version 4 5 Problem Determination and Service Guide...
Страница 8: ...vi DR550 Version 4 5 Problem Determination and Service Guide...
Страница 20: ...xviii DR550 Version 4 5 Problem Determination and Service Guide...
Страница 28: ...xxvi DR550 Version 4 5 Problem Determination and Service Guide...
Страница 78: ...50 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 88: ...60 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 96: ...68 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 102: ...74 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 108: ...80 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 118: ...90 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 178: ...DR2 power cabling Figure 77 DR2 power cabling primary rack 150 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 179: ...Figure 78 DR2 power cabling primary rack and expansion rack Appendix A DR1 and DR2 cabling diagrams 151...
Страница 180: ...Figure 79 DR2 power cabling expansion rack 152 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 185: ...DR1 power cabling Figure 88 DR1 Power Cabling Appendix A DR1 and DR2 cabling diagrams 157...
Страница 186: ...Figure 89 DR1 Power Cabling 158 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 190: ...Figure 95 Storage Controller port identification 162 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 191: ...Figure 96 Expansion Drawer port identification Appendix A DR1 and DR2 cabling diagrams 163...
Страница 192: ...Figure 97 Power Control Assembly PCA port identification 164 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 246: ...218 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 252: ...224 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 257: ......