Chapter
4.
DR550
SSAM
Server
The
DR550
SSAM
Server
is
a
cost-effective,
high-performance,
space-efficient
server
that
uses
advanced
IBM
technology.
The
DR550
SSAM
Server
uses
the
™
microprocessor,
and
is
designed
for
use
in
LAN
clustered
environments.
The
DR550
SSAM
Server
is
a
member
of
the
symmetric
multiprocessing
(SMP)
UNIX
®
servers
from
IBM.
The
DR550
SSAM
Server
is
a
4-EIA
(4U),
19-inch
rack-mounted
server
that
is
configured
as
a
2-core
system
with
2.1
GHz
processors.
The
total
system
memory
installed
is
2048
MB.
The
DR550
SSAM
Server
includes:
v
Six
hot-plug
PCI-X
slots.
v
Feature
Code
3550
Host
Fibre
Ethernet
(SX)
Dual
Port
Adapter
or
Feature
Code
3551
Host
Ethernet
(TX)
Dual
Port
Adapter
(slot
6).
v
Ethernet
(TX)
Dual
Port
Adapter
(slot
5).
v
Feature
Code
3552
Host
Ethernet
(TX)
Dual
Port
Adapter
(slot
3).
Used
for
second
external
host
connection
(optional).
v
Feature
Code
3560
LVD
SCSI
adapter
for
tape
or
optical
storage
(slot
3,
optional).
v
Dual
port
Fibre
Channel
Adapters
(slots
1
&
4).
v
An
integrated
dual
channel
Ultra320
SCSI
controller.
v
Two
10/100/1000
Mbps
integrated
Ethernet
controllers.
v
Eight
front-accessible
disk
bays
supporting
hot-swappable
disks.
(Two
are
populated
with
73
GB
Ultra3
10K
RPM
disk
drives.)
These
disk
bays
are
designed
to
provide
high
system
availability
and
growth
by
allowing
the
removal
or
addition
of
disk
drives
without
disrupting
service.
The
internal
disk
storage
is
configured
as
mirrored
disk
for
high
availability.
The
DR1
model
of
the
DR550
SSAM
Server
has
six
146GB
15K
RPM
internal
disk
drives
and
a
SCSI
RAID
controller.
To
diagnose
problems
with
the
DR550
SSAM
Server,
refer
to
the
Solving
a
problem
section
of
the
Serviceability
Increasing
service
productivity
means
the
system
is
up
and
running
for
a
longer
time.
The
DR550
SSAM
Server
improves
service
productivity
by
providing
the
functions
described
in
the
following
sections.
SSAM
Server
hardware
failures
v
Check
light
indicators.
v
Use
AIX
error
report
(
errpt
)
for
problem
determination.
v
Use
AIX
diagnostics
(
diag
command)
for
problem
determination.
v
Use
other
AIX
checkout
commands
for
problem
determination
(
lsdev,
lsvg,
lspv,
fget_config,
lssrc
,
etc.).
v
The
AIX
snap
command
creates
a
system
snapshot
for
support.
©
Copyright
IBM
Corp.
2008
13
Содержание DR550
Страница 1: ...IBM System Storage DR550 Version 4 5 Problem Determination and Service Guide GA32 0576 00...
Страница 2: ......
Страница 3: ...IBM System Storage DR550 Version 4 5 Problem Determination and Service Guide GA32 0576 00...
Страница 4: ...ii DR550 Version 4 5 Problem Determination and Service Guide...
Страница 8: ...vi DR550 Version 4 5 Problem Determination and Service Guide...
Страница 20: ...xviii DR550 Version 4 5 Problem Determination and Service Guide...
Страница 28: ...xxvi DR550 Version 4 5 Problem Determination and Service Guide...
Страница 78: ...50 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 88: ...60 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 96: ...68 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 102: ...74 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 108: ...80 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 118: ...90 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 178: ...DR2 power cabling Figure 77 DR2 power cabling primary rack 150 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 179: ...Figure 78 DR2 power cabling primary rack and expansion rack Appendix A DR1 and DR2 cabling diagrams 151...
Страница 180: ...Figure 79 DR2 power cabling expansion rack 152 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 185: ...DR1 power cabling Figure 88 DR1 Power Cabling Appendix A DR1 and DR2 cabling diagrams 157...
Страница 186: ...Figure 89 DR1 Power Cabling 158 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 190: ...Figure 95 Storage Controller port identification 162 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 191: ...Figure 96 Expansion Drawer port identification Appendix A DR1 and DR2 cabling diagrams 163...
Страница 192: ...Figure 97 Power Control Assembly PCA port identification 164 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 246: ...218 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 252: ...224 DR550 Version 4 5 Problem Determination and Service Guide...
Страница 257: ......
Страница 258: ...Printed in USA GA32 0576 00...