Table 5. Light path diagnostics (continued)
Lit LED
Cause
Action
Critical error
A critical system error has occurred, such as
nonredundancy on the power modules or a
system error in a blade.
Note:
You can configure the critical error LED
to be either red or amber through the
management module.
v
Check the error log for messages.
v
Look for an error LED on the modules and
blade servers to locate the component:
– If the error LED is on a module, follow
the instructions for the module in this
table.
– If the error LED is on a blade server, see
the documentation that comes with the
blade server.
Management module
System error
A critical error has occurred in the
management module.
v
If your BladeCenter T unit has only one
management module:
1.
Try reseating the management module.
2.
Restart the management module.
If the problem remains, replace the
management module.
v
If your BladeCenter T unit has two
management modules, the BladeCenter T
unit continues to function using the
redundant module. Replace the failed
management module.
Active
Primary management module.
If your BladeCenter T has two management
modules, the Active LED indicates which is
the primary management module.
Power module
System error
A critical error has occurred in the power
module.
Reseat the power module. If the problem
remains, replace the module. If your
BladeCenter T unit has a redundant module
for this power module, the BladeCenter T unit
continues to function using the redundant
module.
Blower module
System error
The blower has failed or is operating too
slowly.
Reseat the blower module. If the problem
remains, replace the blower module as soon as
possible, to regain cooling redundancy. The
BladeCenter T unit continues to function. The
redundant blower module provides cooling to
the BladeCenter T unit and blade servers.
I/O module
System error
A critical error has occurred in the I/O
module.
Reseat the I/O module. If the problem
remains, replace the module.
Chapter 6. Symptom-to-FRU index
93
Содержание BladeCenter T
Страница 1: ...BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 2: ......
Страница 3: ...BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 16: ...xiv BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 20: ...xviii BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 52: ...32 BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 102: ...82 BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 126: ...106 BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 134: ...Taiwan Class A compliance statement 114 BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 138: ...118 BladeCenter T Type 8267 Hardware Maintenance Manual and Troubleshooting Guide ...
Страница 139: ......
Страница 140: ... Part Number 94Y7061 Printed in USA 1P P N 94Y7061 ...