<CLI> list enclosure
Current Machine Local Time: 09/15/2009 02:22:06 PM
_________________________________________________________
| Encl# | Enclosure
| Type
| Version | Status |
|_______|________________|____________|_________|________|
| 0
| Encl0
| Controller | 0107
| Good
|
| 1
| Encl1
| DSM
| 1.06
| Good
|
| 2
| Encl2
| DSM
| 1.08
| Good
|
|_______|________________|____________|_________|________|
19.
Enter
mountstate –getobject –enclosure
and press Enter to list the mount
state of the DSMs. Ensure that each DSM is online.
<CLI> mountstate -getobject -enclosure
Current Machine Local Time: 09/15/2009 02:23:46 PM
_______________________________________________________
| Enclosure# | State
| Type
|
|____________|_______________________|_________________|
| 0
| Online
| Controller
|
| 1
| Online
| DSM
|
| 2
| Online
| DSM
|
|____________|_______________________|_________________|
20.
Enter
list drive
and press Enter to list the drive summary for each disk
drive configured in the storage pool. Ensure that the mount state of all disk
drives inside the replacement DSM are in the online state.
<CLI> list drive
Current Machine Local Time: 09/15/2009 02:25:04 PM
__________________________________________________________________________________________
|Drive#| E:T| SerialNo | Cap | Pool
|Usage|State|Mount State|Ctl0|Ctl1| RPM |FW level|
|______|____|__________|_____|___________|_____|_____|___________|____|____|_____|________|
| 0
| 1:1| 9QK0SWLM |698GB|RAID10_Pool| GRP | OK
| Online
| 1
| 1
| 7200| BC1D
|
| 1
| 1:2| 9QK0V0ZB |698GB|RAID10_Pool| GRP | OK
| Online
| 1
| 1
| 7200| BC1D
|
| 2
| 1:3| 9QK0HQ9V |698GB| --
| GLS | OK
| Online
| 1
| 1
| 7200| BC1D
|
| 3
| 1:4| 9QK0QCGS |698GB| --
| UNA | OK
| Online
| 1
| 1
| 7200| BC1D
|
| 4
| 1:5| 9QK0HQ74 |698GB| --
| UNA | OK
| Online
| 1
| 1
| 7200| BC1D
|
| 5
| 1:6| 9QK0QCEQ |698GB| --
| UNA | OK
| Online
| 1
| 1
| 7200| BC1D
|
| 6
| 2:1| 9QK0SWEJ |698GB|RAID10_Pool| GRP | OK
| Online
| 1
| 1
| 7200| BC1D
|
| 7
| 2:2| 9QK0QCJB |698GB|RAID10_Pool| GRP | OK
| Online
| 1
| 1
| 7200| BC1D
|
| 8
| 2:3| 9QK0QC50 |698GB|RAID10_Pool| GRP | OK
| Online
| 1
| 1
| 7200| BC1D
|
| 9
| 2:4| 9QJ1NG5W |931GB| --
| UNA | OK
| Online
| 1
| 1
| 7200| BC1D
|
| 10
| 2:5| 9QK0SWLY |698GB| --
| UNA | OK
| Online
| 1
| 1
| 7200| BC1D
|
| 11
| 2:6| 9QK0QC85 |698GB|RAID10_Pool| GRP | OK
| Online
| 1
| 1
| 7200| BC1D
|
|______|____|__________|_____|___________|_____|_____|___________|____|____|_____|________|
Drive E:T is Enclosure:Tray; tray numbers start at 1, and tray 1 is the uppermost tray.
Usage:
UNA=unassigned
GRP/SGR=current/stale group member
FOR=foreign
GLS/SGS=current/stale global spare
CBG/SCG=current/stale auto-copy-back global spare
State:
OK=healthy
M=missing
P=PFA predicted failure
U=unreliable (M/P/U can be combined)
INI=initialized
UNS=unsupported (non-IBM) drive PM=path missing
IMD=incompatible metadata with this software version; either assimilate drive
or update controller firmware.
UNF=firmware version unsupported for drive
What to do next
If the problem is not resolved, collect the logs and contact IBM.
Removing and reinserting an active controller
You can resolve some software problems associated with an IBM BladeCenter S
SAS RAID Controller Module by removing and reinserting the same RAID
Controller without significant interruption to the server.
Chapter 11. Troubleshooting and support
173
Содержание BladeCenter S SAS RAID Controller Module
Страница 2: ......
Страница 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Страница 10: ...viii IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 40: ...30 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Страница 102: ...92 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 104: ...94 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 196: ...186 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 200: ...190 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 209: ...Taiwan Class A compliance statement Notices 199...
Страница 210: ...200 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 214: ...204 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 215: ......
Страница 216: ...Part Number 00D9332 Printed in USA 1P P N 00D9332...