9200
Battery
battery_ID
firmware update failed
Explanation:
When the system boots up or a battery is inserted, the controller checks the battery firmware level. If
the firmware does not match the expected version, the controller automatically performs a firmware update. This
alert indicates that a firmware mismatch was detected, but the battery firmware update failed.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears if the battery is removed or a firmware update is initiated.
Operator response:
Acknowledge to clear the alert immediately. Initiate another firmware update by removing and
reinserting the battery. If multiple attempts to update the firmware are unsuccessful, replace the battery (see
“Replacing a Battery Backup Unit” on page 177).
Disk drive informational alerts
The alerts in this section are generated as disk drive state warning messages.
0300
Spare drive
drive_ID
reassigned
Explanation:
Rebuild operation has been started on the drive group and the spare drive has been selected for
rebuild.
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response:
Acknowledge to clear the alert immediately.
0303
Spare drive
drive_ID
copyback complete
Explanation:
The copyback operation has completed and the spare drive is now available.
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response:
Acknowledge to clear the alert immediately.
0304
Drive
drive_ID
position has been updated
Explanation:
By default, the SAS RAID Module system information indicator is not turned on and
System action:
the operator is not notified of this alert by e-mail. Alert clears automatically.
Operator response:
None.
0307
Drive
drive_ID
firmware upgraded
Explanation:
Drive firmware upgrade has completed successfully.
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response:
Acknowledge to clear the alert immediately.
9200 • 0307
128
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module
Содержание BladeCenter S SAS RAID Controller Module
Страница 2: ......
Страница 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Страница 10: ...viii IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 40: ...30 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Страница 102: ...92 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 104: ...94 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 196: ...186 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 200: ...190 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 209: ...Taiwan Class A compliance statement Notices 199...
Страница 210: ...200 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 214: ...204 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 215: ......
Страница 216: ...Part Number 00D9332 Printed in USA 1P P N 00D9332...