D0:
No
response
from
clock
device
XCG0
(BE
PLL)
D1:
No
response
from
clock
device
XCG1
(RC)
D2:
No
response
from
clock
device
XCG2
(Y)
DA:
No
response
from
an
unknown
clock
device
The
following
is
a
list
of
error
log
IDs.
AA:
BE0
attention
line
did
not
get
high
in
step
1
AB:
BE1
attention
line
did
not
get
high
in
step
1
AC:
BE0
attention
line
did
not
get
high
in
step
2
AD:
BE1
attention
line
did
not
get
high
in
step
2
AE:
BE0
attention
line
did
not
get
high
in
step
3
AF:
BE1
attention
line
did
not
get
high
in
step
3
AG:
BE0
attention
line
did
not
get
high
in
step
4
AH:
BE1
attention
line
did
not
get
high
in
step
4
AI:
BE0
attention
line
did
not
get
high
in
step
5
AJ:
BE1
attention
line
did
not
get
high
in
step
5
AK:
BE0
Poll
1
did
not
return
expected
value
AL:
BE1
Poll
1
did
not
return
expected
value
AM:
BE0
Poll
2
did
not
return
expected
value
AN:
BE1
Poll
2
did
not
return
expected
value
AO:
BE0
Poll
3
did
not
return
expected
value
AP:
BE1
Poll
3
did
not
return
expected
value
AQ:
BE0
Poll
4
did
not
return
expected
value
AR:
BE1
Poll
4
did
not
return
expected
value
AS:
BE0
Poll
5
did
not
return
expected
value
AT:
BE1
Poll
5
did
not
return
expected
value
AU:
BE0
VID
value
that
is
read
out
is
not
valid
AV:
BE1
VID
value
that
is
read
out
is
not
valid
AW:
BE0
Poll
7
did
not
return
expected
value
AX:
Hardware
revision
read
from
the
VPD
is
not
supported
or
invalid
AY:
SB0
UART
request
did
not
return
expected
value
AZ:
SB1
UART
request
did
not
return
expected
value
BA:
BE0
does
not
request
configuration
data
BB:
BE1
does
not
request
configuration
data
BC:
BE0
does
not
request
RRAC
training
BD:
BE1
does
not
request
RRAC
training
BE:
BE0
does
not
request
bus
credentials
BF:
BE1
does
not
request
bus
credentials
BG:
BE0
still
needs
attention
after
init
procedure
is
is
done
BH:
BE1
still
needs
attention
after
init
procedure
is
is
done
BI:
BE0
RRAC
training
failed
BJ:
BE1
RRAC
training
failed
BK:
BE0
IOC
init
failed
BL:
BE1
IOC
init
failed
BM:
BE
thermal
alert
from
temperature
monitor
ADT7467
BN:
BE0
thermal
alert
pin
goes
high
BO:
BE1
thermal
alert
pin
goes
high
BP:
BE0
TX_PLL
status
not
correct
during
RRAC
BE
to
BE
init
BQ:
BE1
TX_PLL
status
not
correct
during
RRAC
BE
to
BE
init
BR:
BE0
RX_PLL
status
not
correct
during
RRAC
BE
to
BE
init
BS:
BE1
RX_PLL
status
not
correct
during
RRAC
BE
to
BE
init
BT:
BE0
RX
status
not
correct
during
RRAC
BE
to
BE
cal
(bit
training)
BU:
BE1
RX
status
not
correct
during
RRAC
BE
to
BE
cal
(bit
training)
BV:
BE0
RX
status
not
correct
during
RRAC
BE
to
BE
cal
(parallel
and
slice)
BW:
BE1
RX
status
not
correct
during
RRAC
BE
to
BE
cal
(parallel
and
slice)
BX:
BE0
RX
status
not
correct
during
RRAC
BE
Byte
training
BY:
BE1
RX
status
not
correct
during
RRAC
BE
Byte
training
CA:
BE0
RX
status
not
correct
during
cw_rracup_sb_hr
RRC0
CB:
BE1
RX
status
not
correct
during
cw_rracup_sb_hr
RRC1
CI:
BE0
RX
status
not
correct
during
RRAC
SB
Byte
training
CJ:
BE1
RX
status
not
correct
during
RRAC
SB
Byte
training
CK:
BE0
RX4
phase
cal
status
not
correct
during
SB0
bit
training
CL:
BE1
RX4
phase
cal
status
not
correct
during
SB1
bit
training
CM:
SB0
RX0
phase
cal
status
not
correct
during
SB0
bit
training
CN:
SB1
RX0
phase
cal
status
not
correct
during
SB0
bit
training
CO:
BE0
RX4
parallel
and
slice
cal
status
not
correct
during
SB0
bit
training
24
BladeCenter
QS20
Type
0200:
Problem
Determination
and
Service
Guide
Содержание BladeCenter QS20
Страница 1: ...BladeCenter QS20 Type 0200 Problem Determination and Service Guide SC33 8297 00...
Страница 2: ......
Страница 3: ...BladeCenter QS20 Type 0200 Problem Determination and Service Guide SC33 8297 00...
Страница 8: ...vi BladeCenter QS20 Type 0200 Problem Determination and Service Guide...
Страница 26: ...8 BladeCenter QS20 Type 0200 Problem Determination and Service Guide...
Страница 49: ...v Operating system control file setup Chapter 2 Diagnostics and troubleshooting 31...
Страница 50: ...32 BladeCenter QS20 Type 0200 Problem Determination and Service Guide...
Страница 56: ...38 BladeCenter QS20 Type 0200 Problem Determination and Service Guide...
Страница 80: ...62 BladeCenter QS20 Type 0200 Problem Determination and Service Guide...
Страница 94: ...76 BladeCenter QS20 Type 0200 Problem Determination and Service Guide...
Страница 98: ...80 BladeCenter QS20 Type 0200 Problem Determination and Service Guide...
Страница 99: ......
Страница 100: ...Part Number 42C4969 Printed in USA SC33 8297 00 1P P N 42C4969...