Table 11. B200xxxx Logical partition SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which
components are FRUs.
B200 xxxx Error
Code
Description
Action
8109
During the startup of a partition, a
failure occurred. The startup will not
continue.
1.
Make sure that there is enough memory to start up
the partition.
2.
Check for server firmware updates; then, install the
updates if available.
8111
A problem occurred during the
startup of a partition.
Check for server firmware updates; then, install the
updates if available.
8112
During the startup of a partition, a
failure occurred; the startup will not
continue.
Check for server firmware updates; then, install the
updates if available.
8113
During the startup of a partition, an
error occurred while mapping
memory for the partition startup.
Check for server firmware updates; then, install the
updates if available.
8114
During the startup of a partition,
there was a failure verifying the
VPD for the partition resources
during startup.
Check for server firmware updates; then, install the
updates if available.
8115
During the startup of a partition,
there was a low level
partition-to-partition communication
failure.
Check for server firmware updates; then, install the
updates if available.
8117
During the startup of a partition, the
partition did not start up due to a
system firmware error.
Check for server firmware updates; then, install the
updates if available.
8121
During the startup of a partition, the
partition did not start up due to a
system firmware error.
Go to “Isolating firmware problems” on page 222.
8123
During the startup of a partition, the
partition did not start up due to a
system firmware error.
Go to “Isolating firmware problems” on page 222.
8125
During the startup of a partition, the
partition did not start up due to a
system firmware error.
Go to “Isolating firmware problems” on page 222.
8127
During the startup of a partition, the
partition did not start up due to a
system firmware error.
Go to “Isolating firmware problems” on page 222.
8129
During the startup of a partition, the
partition did not start up due to a
system firmware error.
Go to “Isolating firmware problems” on page 222.
813A
There was a problem establishing a
console.
Go to “Isolating firmware problems” on page 222.
8140
Informational system log entry only.
No corrective action is required.
8141
Informational system log entry only.
No corrective action is required.
8142
Informational system log entry only.
No corrective action is required.
8143
Informational system log entry only.
No corrective action is required.
Chapter 2. Diagnostics
37
Содержание BladeCenter JS22
Страница 1: ...BladeCenter JS22 Type 7998 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter JS22 Type 7998 Problem Determination and Service Guide...
Страница 14: ...xii JS22 Type 7998 Problem Determination and Service Guide...
Страница 248: ...234 JS22 Type 7998 Problem Determination and Service Guide...
Страница 286: ...272 JS22 Type 7998 Problem Determination and Service Guide...
Страница 294: ...280 JS22 Type 7998 Problem Determination and Service Guide...
Страница 298: ...284 JS22 Type 7998 Problem Determination and Service Guide...
Страница 308: ...294 JS22 Type 7998 Problem Determination and Service Guide...
Страница 313: ......
Страница 314: ...Part Number 44W2359 Printed in USA 1P P N 44W2359...