Table 11. B200xxxx Logical partition SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 7998,” on page 235 to determine which components are CRUs and which
components are FRUs.
B200 xxxx Error
Code
Description
Action
5137
A problem occurred during the
startup of a partition. There was an
error writing the partition main
storage dump to the partition load
source. The main store dump startup
will continue.
Look for other errors and resolve them.
5145
A problem occurred during the
startup of a partition. There was an
error writing the partition main
storage dump to the partition load
source. The main store dump startup
will continue.
Look for other errors and resolve them.
5148
A problem occurred during the
startup of a partition. An error
occurred while doing a main storage
dump that would have caused
another main storage dump. The
startup will not continue.
Go to “Isolating firmware problems” on page 222.
5149
A problem occurred during the
startup of a partition while doing a
Firmware Assisted Dump that would
have caused another Firmware
Assisted Dump.
Check for server firmware updates; then, install the
updates if available.
514A
A Firmware Assisted Dump did not
complete due to a copy error.
Check for server firmware updates; then, install the
updates if available.
542A
A Firmware Assisted Dump did not
complete due to a read error.
Check for server firmware updates; then, install the
updates if available.
542B
A Firmware Assisted Dump did not
complete due to a copy error.
Check for server firmware updates; then, install the
updates if available.
543A
A Firmware Assisted Dump did not
complete due to a copy error.
Check for server firmware updates; then, install the
updates if available.
543B
A Firmware Assisted Dump did not
complete due to a copy error.
Check for server firmware updates; then, install the
updates if available.
543C
Informational system log entry only.
No corrective action is required.
543D
A Firmware Assisted Dump did not
complete due to a copy error.
Check for server firmware updates; then, install the
updates if available.
6006
During the startup of a partition, a
system firmware error occurred
when the partition memory was
being initialized; the startup will not
continue.
Go to “Isolating firmware problems” on page 222.
600A
A problem occurred during the
startup of a partition. The partition
could not reserve the memory
required for IPL.
Contact IBM support, as described in Appendix A,
“Getting help and technical assistance,” on page 281.
Chapter 2. Diagnostics
35
Содержание BladeCenter JS22
Страница 1: ...BladeCenter JS22 Type 7998 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter JS22 Type 7998 Problem Determination and Service Guide...
Страница 14: ...xii JS22 Type 7998 Problem Determination and Service Guide...
Страница 248: ...234 JS22 Type 7998 Problem Determination and Service Guide...
Страница 286: ...272 JS22 Type 7998 Problem Determination and Service Guide...
Страница 294: ...280 JS22 Type 7998 Problem Determination and Service Guide...
Страница 298: ...284 JS22 Type 7998 Problem Determination and Service Guide...
Страница 308: ...294 JS22 Type 7998 Problem Determination and Service Guide...
Страница 313: ......
Страница 314: ...Part Number 44W2359 Printed in USA 1P P N 44W2359...